Fitting Instruction
1. Identify the most appropriate position for the shower seat ensuring the product is at a comfortable
height and distance for showering.
2. The product can be folded upwards for more convenient storage so please ensure there is sufficient
space above the fixing position to allow for this.
3. Place the shower seat in the desired position on the wall and using the hole centres located on the wall
bracket as a template, mark the screw fixing positions on the wall surface, ensuring the product is level.
ALL FIXING HOLES MUST BE USED (See Fig.1).
4. Drill the holes in the marked positions using a masonry drill. If the product is to be fitted onto a
ceramic tiled wall, a ceramic drill bit should be used.
5. Insert wall plugs (if applicable) flush to the surface of the wall. If fitting to a tiled surface, the wall plugs
should be inserted below the surface of the tile to avoid cracking.
6. Insert the fixings through the holes located on the wall bracket and secure to the wall.
NOTE: Do not use countersink screws. Do not enlarge fixing holes. This can reduce the strength of
the frame and invalidate the safe working load stated.
7. Once secured in position, clip the chrome cover plate over the wall bracket to conceal the wall fixings
and complete the assembly of the shower seat - See Fig.2
8. Always check the shower seat is securely fastened to the wall before use.
Fig.1
Additional Information
This product must be fitted to solid brick, concrete block walls or similarly strong materials offering
appropriate support for the maximum safe working load.
NOTE: Lightweight thermal blocks, aerated hollow brickwork or prefabricated partition walls will
reduce the maximum safe working load of this product.
Maximum safe working load for the shower seat is 100kg
For details of the other items in the Croydex range please visit our website: www.croydex.com
Croydex Ltd, Central Way, Andover, Hants, SP10 5AW, UK
Tel: +44 (0) 1264 365881