Aeon Labs AEOEZW100 Краткое руководство по эксплуатации - Страница 3
Просмотреть онлайн или скачать pdf Краткое руководство по эксплуатации для Аксессуары Aeon Labs AEOEZW100. Aeon Labs AEOEZW100 11 страниц. Routing multisensor
The unit is operated by batteries. Use only batteries of correct type. Never mix old and new batteries in the same device. Used batteries
contain hazardous substances and should not be disposed of with household waste!
Battery Type: 2 * CR123A
Installation Guidelines
You can install the Multisensor wherever you want thanks to the enclosed accessories. You can use either the mounting arm or the tape to
install the Multisensor. With the tape the Multisensor will be static in that position. If you want to use the mounting arm simply install the
mounting arm wherever you want and screw in the Multisensor. With the mounting arm you will be able to adjust the Multisensor exactly in
whatever direction you wish.
Behavior within the Z-Wave network
I
On factory default the device does not belong to any Z-Wave network. The device needs to join an existing wireless network to
communicate with the devices of this network. This process is called Inclusion. Devices can also leave a network. This process is
called Exclusion. Both processes are initiated by the primary controller of the Z-Wave network. This controller will be turned into exclusion
respective inclusion mode. Please refer to your primary controllers manual on how to turn your controller into inclusion or exclusion mode.
Only if the primary controller is in inclusion or exclusion mode, this device can join or leave the network. Leaving the network - i.e. being
excluded - sets the device back to factory default.
If the device already belongs to a network, follow the exclusion process before including it in your network. Otherwise inclusion of this
device will fail. If the controller being included was a primary controller, it has to be reset first.
Power on the MultiSensor. The MultiSensor's LED will blink slowly when you short press the Action Button. Set the primary controller into
inclusion mode (If you don't know how to do this, refer to its manual). Press the Action Button. If the inclusion is successful, the
MultiSensor's LED will be kept turning on for 8 seconds when you short press the Action Button. If the LED is still in slow blink, you need to
repeat the process from setting the controller into inclusion mode onward. If you want to reset the Multisensor to its factory default state you
can do this by pressing and holding the action button for at least 20 seconds. During this time the LED will blink faster and faster. After that
time the LED will stay solid for 2 seconds to indicate success.