PUSH BUTTON SWITCHES & DESCRIPTION OF FUNCTION
1. POWER KEY
Press to turn unit "ON" or "OFF".
2. FUNCTION
Press this key to select refrigeration or dehumidification.
3. TEMPERATURE REGULATION KEY (UP)
This key raises the preset temperature by 1℃ each time it is pressed to a maximum of 30℃
4. TEMPERATURE REGULATION KEY (DOWN)
This key lowers the preset temperature by 1℃ each time it is pressed to a minimum of 17℃.
In normal conditions, the temperature data which appears on the panel is the ambient
room temperature, not the temperature which is set by the user. When the user has
adjusted and set the temperature to the desired level, the data on the panel will return to
the ambient room temperature 5 seconds later.
The ambient temperature will descend or change according to the temperature which is
set by the user, but the temperature descendant time and speed will depend on the
environment and space where it operates.
For example, if the ambient temperature is too hot or the room is too large, the rate
at which the temperature descends will be slow.
4
5. L.E.D. DISPLAY
Indicates the current room temperature or the timer setting. If the
pre-set temperature is adjusted by the user the display will return back
to room temperature automatically.
Error Display
E1: Indicates open circuit or short circuit in room temperature sensor.
E2: Indicates open circuit or short circuit in evaporator temperature sensor.
E3: Indicates a fault in the compressor air outlet temperature sensor.
E4: Indicates a data transmission error between the compressor drive plate and main PCB.
E5: Indicates IC error.
E7: Indicates the water tank is full inside.
Please contact an authorized service centre if any of the above error messages are shown.
6. FAN SPEED
Press to select LOW, MEDIUM, HIGH or AUTO fan speed.
If "AUTO" is selected, the unit operates at maximum cooling
capacity when the room temperature less the setting temperature
is above 2℃.
When the room temperature less the set temperature is below
2℃, the unit operates at middle cooling capacity.
When the room temperature equals the set temperature, the
unit operates at minimum capacity.
If "HIGH" is selected, the unit operates at maximum cooling
capacity regardless of the pre-set temperature. Similar operation is
applied when "MEDIUM" OR "LOW" is manually selected.
7. PROGRAMMABLE
Programmable timer ON/OFF key.
TIMER
TIMER-ON: The timer-on key is used to turn the unit on
automatically when the set time is reached.
(The indicator light will be turned on when the timer is
functioning.)
1. Press the "TIMER" key at stand-by status to set the time.
Choose the function desired (refrigeration or dehumidification.)
2. Once the set hour has come to an end, the unit will turn on
5