6. ADJUSTMENTS
6.1 INITIAL ADJUSTMENT
6.1.1 Adjustment of DC Offset Voltage (Fig.1)
After having turned on the power, adjust VR301 and VR302 of
VOLTAGE
AMP
assembly
inside the rear
box
so that the
voltage between the speaker terminals
( + and
—) becomes
within +10mV.
6.1.2 Adjustment of the Idle Electric Current (Fig.2)
Adjust VR402 so that the voltage between the emitter resistors
(R460, R466) of POWER
R I/O assembly (between the idle
check terminals) becomes 170mV.
Note : When on the left side, adjust VR401
of POWER
L I/O
assembly. Also reverse the polarity of the voltage meter.
(9)
Reh (VR302)
a
Leh (VR301)
Rear side
Voltage meter
Fig. 1 DC offset voltage adjustment
Voltage meter
A-09
6.2 AGING
After having adjusted the initialization, carry out aging for 5
minutes.
6.3 FINAL ADJUSTMENT
1. Adjust the DC offset voltage to within £10mV with VR301
and VR302.
2. After this, carry out idle current adjustment of the voltage
value with VR401 and VR402 to 150mV
+5mV.
R side heat sink assy
Voltage meter
(Approx. 250mvV)
VR402
Fig. 2 Idle current adjustment