Pioneer 504CMX - PDP - 50" Plasma Panel Справочное руководство по командам - Страница 7

Просмотреть онлайн или скачать pdf Справочное руководство по командам для Монитор Pioneer 504CMX - PDP - 50" Plasma Panel. Pioneer 504CMX - PDP - 50" Plasma Panel 18 страниц. Plasma display panel rs-232c commands

Pioneer 504CMX - PDP - 50
RS-232C Adjustment Mode
Under the connection conditions shown below, operation using a combination cable is assured up to 16 sets.
1 Length of RS-232C cable connecting PC to PDP-504CMX/PDP-50MXE1/PDP-50MXE1-S: 5 m
Conditions:
2 Combination cable length: 5 m each
3 Wire specifications for linking cable: Mini Din 6-pin straight (7 strand cable)
Note
For details on the number of displays that can be connected in series using the video OUT terminal (INPUT1, 4), refer to
section 2.3, 'Part Names'.
5
PC
RS-232C
5m
Combination cable 5m
For 1 strand, suitable for AWG28:
Cross-section area = 0.08 mm
7 strands × π r
= 7 × 3.14 × 0.06
2
PDP-504CMX
PDP-50MXE1
PDP-50MXE1-S
1
OUT
IN
2
OUT
IN
3
OUT
IN
#
2
≠ 0.08 mm
2
2
= 0.079 mm
2