on the level absorbs the acoustic wave re-
Foam
fl ection which might cause malfunction of the level
meter. For mounting fi nd the location where the
foaming is as low as possible (Fig. 5).
Emitted acoustic signal must not be affected by
near objects (ladders, mixers, propellers, etc.),
stream of fi lling, air fl ow, etc. (Fig. 6).
Fig. 6: Minimum distance of the level meter to nearby objects in
Do not install the level meter in or above the
Fig. 7: Level meter installation outside the infl uence of fi lling circulation
In case the level of
We recommend to consult the use with the manufacturer.
© Dinel, s.r.o.
ULM–53
the tank
bulk-solid materials is measured, the measurement range is reduced.
!
Fig. 5: Thick foam on the surface
ULM–53–02 ; 10
ULM–53–06
ULM–53–20
x – distance to the edge
c – measurement range
fi lling point. (Fig. 7).
x > 1/12 c
(min. 200 mm)
x > 1/8 c
(min. 200 mm)
x > 1/10 c
(min. 200 mm)
of the longest object
of the level gauge