3. Warning

According to certain national standard, there are some limitations of installing water heater in the
bathroom.
Ariston Thermo Group (China) Co., Ltd. bears no responsibility for damages result from user's
installation and operation which are against instructions of this manual. Product installation must
be implemented by technicians authorized or certified by Ariston and we don't bear any
responsibility in the process of the installation carried by users themselves.
It is more than necessary to pay attention to the following issues:
·Must use original safety valve which is attached to product package.
·Product package must be intact and not replaced by other parts.
·Product installation must be implemented by technicians authorized or certified by Ariston and
expansion bolts must be fastened.
·Make sure that power supply voltage is the same with that on product tag and that ammeter, outlet
(16A outlet) and cable diameter (related with 16A outlet) are in conformity with product's rated
current.
·According to national standard, check for grounding condition, outlet must be connected with
earth wire which is totally separated with neutral wire. It
is
strictly prohibited of using water heater without reliable
grounding condition.
·Do not use any electricity adapter and extension cable to
adapt to water heater's plug or use any other plug to
adapt to its outlet. Please do not use terminal board
(figure d and e).
·Water heater should be separately connected to the
circuit where there is no other electric appliance.
·Water heater and outlet should be installed at a dry
place where is free from water.
·Line cord used by this product is specially designed, if
there's any damage it could only be changed by
technicians authorized or certified by Ariston.
·If user's in-house power supply does not meet the
standard requirement then it's suggested that an
independent leakage protector should be installed into
water heater's loop.