Accessing the settings - adjustment parameters
RESERVED FOR TECHNICAL ASSISTANCE
To access the Parameters proceed as follow:
- switch Off the appliance
- switch On the appliance and within 1 minute simultaneously
press the 3 and 4 buttons for 3 seconds
- the display showsLO.
To select the others parameters press 4 button.
To access to the parameters press the ON/OFF button, the
display shows the value of the parameter.
To modify the value press the 3 and 4 buttons.
To save the new value press ON/OFF.
description
notes
Model and type of gas selection
Lo
RESERVED FOR TECHNICAL ASSISTANCE Only if
the gas or PCB is changed see "gas setting" table
Post-ventilation time
L1
setting.
Adjust the Gas
burner pressure MIN
L2
Read the pressure on the manometer and verify
on "gas setting" table
Adjust the Gas
burner pressure MAX
L3
Read the pressure on the manometer and verify
on "gas setting" table
L4
NOT ACTIVE
L5
NOT ACTIVE
Soft ignition
L6
Read the pressure on the manometer and verify
on "gas setting" table
L7
NOT ACTIVE
L8
DHW Start delay time
L9
Main P.C.B. software version
LA
HMI software version (Remote Control)
Fan speed
automatic adjustment
Lb
This parameter must be used if the following
components are replaced / reassembled: PCB, fan,
combustion chamber, heat exchanger, exhaust cover.
LC
Stepper motor reset
Ld
Maximum limited pressure
LE
Minimum limited pressure
COMMISSIONING
value
0 = 90 sec.
(if set temperature ≥ 50°C)
0 = 30 sec.
0
(if set temperature < 50°C)
FACTORY SETTIG
1 = 30 sec.
from -9 to 9
from -9 to 9
from 0 to 50
5
10 = 1 sec.
0= default
0
1 = re-adapt
00
0= Auto
/