Aeotec ZWA019 Руководство пользователя - Страница 5

Просмотреть онлайн или скачать pdf Руководство пользователя для Аксессуары Aeotec ZWA019. Aeotec ZWA019 9 страниц. Water sensor
Также для Aeotec ZWA019: Руководство (3 страниц), Руководство пользователя (13 страниц), Руководство пользователя (9 страниц)

Aeotec ZWA019 Руководство пользователя
Tampering
Water protection
Button Function.
Push Type
Long Press 5s
Long Press 10s
Short Press
3 Times Short Press

Advanced Functions.

Communication test.
This utilizes the Power Level command class to determine the health between the Water Sensor 7 and your Z-Wave
gateway. This will tell you if the Water Sensor 7 has a healthy connection to your system and is a great method of
debugging connectivity issues.
1. Set Parameter #4 to value #1
2. Double click the Tamper Switch.
3. Result:
Green LED blinks once - success
Red LED blinks 3x times - failure
Firmware-Update over the Air.
This device is capable of receiving a new firmware 'over the air'. The update function needs to be supported by the central
controller. Once the controller starts the update process, perform the following action to confirm the firmware update:
1. Wake Up the device by removing the cover.
2. The hit the tamper switch once.
Send a wake up notification.
In order to send your sensors new configuration commands from your Z-Wave controller or gateway, it will need to be
woken up.
1. Wake Up the device by removing the cover.
2. The hit the tamper switch once.
Note: Water Sensor 7 remains awake until the housing is closed again.
If either Tamper Switch 1 or 2 is activated the device blinks red
one time with ½ second duty cycle if within range of Controller.
The device blinks red three times with ½ second duty cycle if out of
range of Controller
When operation button is Short Pressed the LED illuminates red
three seconds in case of Water Leakage detected and Green if
no Leakage detected.
Function
Description
Pending reset
LEDs start indication Waiting for Reset.
Reset
Initiates Device Reset Locally.
Tamper
Sends Wake Up notification.
Sequence
See Learn Mode.