Ariston RT45PE-VN Руководство - Страница 5

Просмотреть онлайн или скачать pdf Руководство для Водонагреватель Ariston RT45PE-VN. Ariston RT45PE-VN 26 страниц. Electric instant water heater

Screen
Problem
display
Flow rate too
/
small
Triangle icon
/
blinking
house light
frickering
ON
when heating
ELCB
Heating
lamp
Icon
(if any)
1) Make sure the water pressure is big enough to provide
you confortable water flow rate. (for water heater without
pump, water tank should be at least 3 meters higher than
water heater)
2) Make sure there are no dirty blocks the water flow, by
/
/
cleaning the filter, which is built in the water valve.
3) Make sure there are no dirty blocks the nozzles of
shower head.
4) Make sure there are no bottle neck Between the water
inlet pipe and the main water supplier point;
/
/
1) Check if inlet temp higher than setting temp.
1) Measuring the actual voltage WHEN heating to make
sure voltage drop not too big. (voltage drop should be less
ON
ON
than 10%).
By increasing sectional area of, or reducing length of the
power supply cable could solve the flickering problem.
checking actions
3