Notes for the wire connection ports:
N – Power input for neutral
L – Power input for live
IN – Input for load power supply
OUT1 – Output for load 1
OUT2 – Output for load 2
S1 – External switch control for load 1
S2 – External switch control for load 2
Inclusion/Exclusion
On factory default the device does not belong to any Z-Wave network. The device needs to be added to an existing wireless network to communicate with the
devices of this network. This process is called Inclusion.
Devices can also be removed from a network. This process is called Exclusion. Both processes are initiated by the primary controller of the Z-Wave network. This
controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is then performed doing a special manual action right on the device.
Inclusion
Press the action button two times for secure inclusion
Exclusion
Short press the Action button for exclusion

Product Usage

Click one time 1 Send out a Node info without Security CC in command class list
Quick press 2 times Send out a Node info that contains Security CC in the command
Quick press 4 times Activate the automatic identification mode for external switch S1. The blue LED will fast blink to indicate the Nano Switch is in this mode.
Quick press 6 times Activate the automatic identification mode for external switch S1. The green LED will fast blink to indicate the Nano Switch is in this mode.
Quick trouble shooting
Here are a few hints for network installation if things dont work as expected.
1.
Make sure a device is in factory reset state before including. In doubt exclude before include.
2.
If inclusion still fails, check if both devices use the same frequency.
3.
Remove all dead devices from associations. Otherwise you will see severe delays.
4.
Never use sleeping battery devices without a central controller.
5.
Dont poll FLIRS devices.
6.