Cardboard items can be used for simulated height testing before actual
installation.
Testing process:
Step 1 Leave the device stationary or fixed
Step 2 Referring to Figure 5.4 or Figure 5.5, place the item above or below the
probe of the device and block the probe (white part) so that d>15cm and d<30cm.
This can be used to simulate the situation where the trash is full;
(Note: 1 Due to the blind area of the ultrasonic probe itself, accurate data should
be measured when the distance d>15cm.)
(Note: The sensor can detect the distance d from the device probe to the object.
This distance is also a sign that the trash can be empty or full. The sensor detects
the distance d from the device probe to the item is less than 30cm (30cm is the
default alarm threshold, this value can be When the serial port or the platform is
modified downwards), the trash bin is full, otherwise the display is not full.)
Method 1: Place the object over the probe
Measured object
Equipment probe
θ=90°is the best
Method 2: Place the Object Under the Probe
θ
θ=90°is the best
Indicates that the location of the device and the object is correct
×:
Beijing Dingtek Technology Corp., Ltd.
http://www.dingtek.com
Room A209, Flounder Business Park, Shunbai Road 12, Chaoyang District, Beijing, China 100022
d
θ
θ1
Figure 5.4
θ1
×
Figure 5.5
×
;
Tel:86-10-64718863,64753700
θ1
×
θ1
×