Ariston genus evo 30 CF Инструкции по установке и обслуживанию - Страница 36

Просмотреть онлайн или скачать pdf Инструкции по установке и обслуживанию для Котел Ariston genus evo 30 CF. Ariston genus evo 30 CF 48 страниц. Wall-hung
Также для Ariston genus evo 30 CF: Руководство пользователя (16 страниц)

Ariston genus evo 30 CF Инструкции по установке и обслуживанию
area tecnica
descrizione
note
2. 6 FORZAMENTI MANUALI CALDAIA
2. 6. 0 Attivazione modo manuale
2. 6. 1 Forzamento pompa caldaia
2. 6. 2 Forzamento ventilatore
2. 6. 3 Forzamento valvola
deviatrice
2. 7 TEST & UTILITIES
2. 7. 0 Spazzacamino
Ruotare l'encoder per selezionare ON e premere OK.
La caldaia viene forzata alla massima pot. riscaldamento.
Ruotando l'encoder è possibile selezionare il
funzionamento
alla massima pot. sanitario o alla potenza minima.
E' possibile attivare la Funzione Spazzacamino (Chimney
attiva) premendo per 10 secondi il Tasto Reset.
2. 7. 1 Ciclo Disareazione
Ruotare l'encoder per selezionare ON e premere OK.
E' possibile attivare il Ciclo Disareazione premendo per 5
secondi il tasto ESC.
2. 8 RIPRISTINO IMPOSTAZIONI DI FABBRICA
2. 8. 0 Ripristino delle impostazioni
di fabbrica del menu 2
Per resettare tutti i parametri alle impostazioni iniziali di
fabbrica premere il tasto OK.
4 PARAMETRI ZONA 1
4. 0 IMPOSTAZIONE TEMPERATURE ZONA 1
4. 0. 2 Impostazione Temperatura
Fissa Riscaldamento
Da impostare per termoregolazione a temperatura fi ssa
(vedi 421)
4. 2 IMPOSTAZIONE ZONA 1
4. 2. 1 Selezione Tipologia
Termoregolazione in base
alle periferiche connesse
Per attivare la
Termoregolazione premere
il tasto AUTO. Sul display
compare il simbolo
36
range
0 = OFF
0
1 = ON
0 = OFF
0
1 = ON
0 = OFF
0
1 = ON
0 = Sanitario
0
1 = Riscaldamento
0 = OFF
0
1 = ON
0 = OFF
0
1 = ON
Reset?
OK = Si, ESC = NO
da 35 a 82 (°C)
70
0 = Temperatura
1
fi ssa di
mandata
1 = Dispositivi
ON/OFF
2 = Solo sonda
ambiente
3 = Solo Sonda
Esterna
4 = Sonda ambiente
+ sonda esterna
technical area
description
notes
2. 6 BOILER MANUAL SETTINGS
2. 6. 0 Manual mode activation
2. 6. 1 Boiler pump control
2. 6. 2 Fan control
2. 6. 3 Fan control
2. 7 TEST & UTILITIES
2. 7. 0 Test mode
Turn the encoder to select ON and press OK.
The boiler is forced to the maximum heating power.
Turning the encoder allows for selecting the D.H.W.
maximum or minimum power operating mode
It is possible to activate the Cleaning Function (Chimney
active) by pressing the Reset button for 10 seconds.
2. 7. 1 Air purge Function
Turn the encoder to select ON and press OK.
The Deaeration Cycle can be activated by pressing the ESC
button for 5 seconds.
2. 8 RESET MENU' 2
2. 8. 0 Reset factory settings
To reset all default parameter settings, press the OK button
4 ZONE 1 PARAMETER
4. 0 ZONE 1 TEMPERATURE SETTING
4. 0. 2 Fix temperature central
heating
To set only with Fixed Flow Temperaure of
Thermoregulation (see 421)
4. 2 ZONE 1 SETTING
4. 2. 1 Select Type of
Thermoregulation
To enabled thermoregulation
press Auto button.
On the dispaly will appear the
symbol
value
0 = OFF
0
1 = ON
0 = OFF
0
1 = ON
0 = OFF
0
1 = ON
0 = OFF
0
1 = ON
0 = OFF
0
1 = ON
0 = OFF
1 = ON
Reset OK = yes
ESC = no
from 35 to 82 (°C)
70
(high temperature)
0 = Fixed Flow
1
Temperature
1 = Basic
Thermoreg.
2 = Room sensor
3 = Outdoor Temp.
only
4 = Room sensor +
outdoor Temp.