Ariston micro SYSTEM 15 RFFI Руководство по установке - Страница 15

Просмотреть онлайн или скачать pdf Руководство по установке для Котел Ariston micro SYSTEM 15 RFFI. Ariston micro SYSTEM 15 RFFI 44 страницы. Type c boilers
Также для Ariston micro SYSTEM 15 RFFI: Руководство пользователя (16 страниц)

Ariston micro SYSTEM 15 RFFI Руководство по установке
4.2
C
P
ONTROL
ANEL
L
:
EGEND
A - On/Off button
B - On/Off L.E.D. green (frost protection active)
C - Central Heating button
D - Cental Heating active L.E.D. green
E - Ignition failure (lockout) and/or overheat reset button
F - Ignition failure (lockout) and/or overheat L.E.D. red
G - Central heating temperature adjustment
H - Energy Saving System (ESS)
I
- Knock-out for time clock
J - Heating system pressure gauge
4.3
R
EMOVING THE
F
P
RONT
ANEL
1
A
2
3
F
. 4.1
IG
In order to access the inside of the boiler, it is necessary to
unscrew the fastening screws "A" of the control panel located on
the lower part of the panel itself.
The control panel moves downward and when pulled forward
rotates on two lateral hinges.
The panel stays in a semi-horizontal position, which allows
access to the inner parts of the boiler.
In order to increase the manoeuvring space, it is possible to raise
the control panel and rotate it to a fully horizontal position.
To dismantle the front casing panel it is necessary to:
1 - Remove the two screws "B";
2 - Move the front casing panel up and lift forward.
4
5
15
B