Setting
0
1
2
3
4
5
6
7
8
Parameter 20: Temperature Scale Setting
Configure temperature sensor scale type, Temperature to report in Celsius or Fahrenheit.
Size: 1 Byte, Default Value: 0
Setting
0
1
Parameter 21: Temperature Threshold Value toReport
Change threshold value for change in temperature to induce an automatic report for temperature sensor. Scale is identical setting in Parameter No.20.
Setting of value 20 can be a change of -2.0 or +2.0 (C or F depending on Parameter No.20) to induce automatic report or setting a value of 2 will be a
change of 0.2(C or F).
Size: 2 Byte, Default Value: 20
Setting
0 - 250
Parameter 22: Light intensity Threshold Value to Report
Change threshold value for change in light sensor to induce an automatic report for temperature sensor.
Size: 2 Byte, Default Value: 100
Setting
0 - 10000
Parameter 23: Temperature Sensor ReportInterval
This parameter is configured the time interval for temperature sensor report. This value is larger, the battery life is longer. And the temperature value
changed is not obvious.
Size: 2 Byte, Default Value: 3600
Setting
1 - 32767
Parameter 24: Light Sensor Report Interval
This parameter is configured the time interval for light sensor report. This value is larger, the battery life is longer. And the light intensity changed is not
obvious.
Size: 2 Byte, Default Value: 3600
Setting
1 - 32767
Parameter 30: Temperature Offset Value
The current measuring temperature value can be add and minus a value by this setting. The scale can be decided by Parameter Number 20.Temperature
Offset Value = [Value] * 0.1(Celsius / Fahrenheit)
Size: 2 Byte, Default Value: 0
Setting
-200 - 200
Parameter 31: Light Intensity Offset Value
The current measuring light intensity value can be add and minus a value by this setting.
Size: 2 Byte, Default Value: 0
manuals-backend.z-wave.info/make.php?lang=en&sku=AEOEZWA005&cert=ZC10-18046087&type=mini
manuals-backend.z-wave.info/make.php?lang=en&sku=AEOEZWA005&cert=ZC10-18046087&type=mini
Description
Disable
Red
Green
Blue
Yellow
Pink
Cyan
Purple
Orange
Description
Celsius (C)
Fahrenheit (F)
Description
Value in 0,1°
Description
Lux.
Description
Second.
Description
Second.
Description
Temperature Offset Value = [Value] * 0.1(Celsius / Fahrenheit)