Ariston microSYSTEM 10 RFFI Руководство по установке - Страница 6

Просмотреть онлайн или скачать pdf Руководство по установке для Котел Ariston microSYSTEM 10 RFFI. Ariston microSYSTEM 10 RFFI 20 страниц. Type c boilers
Также для Ariston microSYSTEM 10 RFFI: Руководство пользователя (16 страниц), Инструкции по обслуживанию (24 страниц)

Ariston microSYSTEM 10 RFFI Руководство по установке
132
132
C
E
F
. 2.1
IG
2.6
M
OUNTING THE
2.7
E
C
LECTRICAL
The type C appliances (in which the combustion circuit, air vent intake and
combustion chamber are air-tight with respect to the room in which the
appliance is installed) can be installed in any type of room.
Secondary ventilation is not required with this boiler. The boiler must be installed on
a solid, non-combustible, permanent wall to prevent access from the rear.
60 mm
A
PPLIANCE
Fasten the boiler in place using the template and anchors supplied with the unit. It is
highly recommended that a spirit level be used to position the boiler so that it is
perfectly level.
For additional information, please consult the instructions contained in the
connection kit and the flue kit.
For safety purposes, have a competent person carefully check the electrical system
ONNECTION
in the property, as the manufacturer will not be held liable for damage caused by the
failure to earth the appliance properly or by anomalies in the supply of power. Make
sure that the residential electrical system is adequate for the maximum power
absorbed by the unit, which is indicated on the rating plate. In addition, check that the
section of cabling is appropriate for the power absorbed by the boiler.
The boiler operates with alternating current, as indicated in the technical information
table in section 7, where the maximum absorbed power is also indicated. Make sure
that the connections for the neutral and live wires correspond to the indications in the
diagram. The appliance electrical connections are situated on the reverse of the
control panel under the inspection cover (see the servicing manual for further
information)
I
MPORTANT
In the event that the power supply cord must be changed, replace it with one with the
same specifications. Make the connections to the terminal board located within the
control panel, as follows:
- The yellow-green wire should be connected to the terminal marked with the "
symbol;
- The blue wire should be connected to the terminal marked "N";
- The brown wire should be connected to the terminal marked "L".
Note: The diagrams for the electrical system are indicated in section 2.12.
2.4
O
VERALL
L
:
EGEND
A
= Central Heating Flow (3/4")
C
= Gas Inlet (3/4")
E
= Central Heating Return (3/4")
mm = Clearances
450 mm
2.5
C
LEARANCES
In order to allow for access to the interior of the boiler for
maintenance pur poses, the boiler must be installed in
compliance with the minimum clearances indicated in F
!
6
D
IMENSIONS
. 2.1
IG
"