Aeotec ZWA039 Краткое руководство по эксплуатации - Страница 9
Просмотреть онлайн или скачать pdf Краткое руководство по эксплуатации для Датчики безопасности Aeotec ZWA039. Aeotec ZWA039 12 страниц. Temperature & humidity sensor
- 2 0 0 ~ 2 0 0
Parameter 15: Offset value for Humidity
Can add or minus this setting value to calibrate humidity when checked.
Unit: %.
Size: 1 Byte, Default Value: 0
Setting
- 5 0 ~ 5 0
Parameter 16: Check interval for Upper/ Lower Watermark value on Parameter 5 ,6,7 and 8.
This value determines how often aerQ Sensor checks for upper/lower watermark value in temperature
or humidity on Parameter 5 ,6,7 and 8. Value is set in minutes.
Size: 1 Byte, Default Value: 15
Setting
1 - 255
Parameter 64: Switch the unit of Temperature report.
This value allows to switch between Celcius and Fahrenheit unit of temperature report.
Size: 1 Byte, Default Value: 1 (EU version) or 2 (US version).
Setting
1
2
Parameter 65:
S e n s o r r e p o r t a f t e r
This value determines which sensor report will be sent after the inclusion is complete.
Size: 1 Byte, Default Value: 15.
Setting (
field)
b i t
Bit 0
Bit 1
Bit 2
Bit 3
-20 - 20
d e g r e e s
Description
-50 - 50
%
Description
1 - 255 minutes
Description
Celcius
Fahrenheit
inclusion.
Description
Battery report. (0 = disable, 1 = enable)
Temperature sensor report. (0 = disable, 1 = enable)
Humidity sensor report. (0 = disable, 1 = enable)
Dew point sensor report. (0 = disable, 1 = enable)