Aeotec AEOEZW116 Краткое руководство по эксплуатации - Страница 3
Просмотреть онлайн или скачать pdf Краткое руководство по эксплуатации для Измерительные приборы Aeotec AEOEZW116. Aeotec AEOEZW116 11 страниц. Single nano switch with measuring
Также для Aeotec AEOEZW116: Руководство (16 страниц)
OUT1 ? Output for load 1
OUT2 ? Output for load 2
S1 ? External switch control for load 1
S2 ? External switch control for load 2
1. Shut off the main circuit breaker of your home for safety during the installation and ensure the wires are not short circuited during the installation which will
cause damage to the Nano Switch.
Note: Your home?s main circuit breaker must support the overload protection for safety.
2. Preparing connection wires 14 AWG power wires for Input/ Output. 18 AWG copper wires for external manual switch. Use the wire stripper cut the metallic part
of the connection wire and make sure the length of the metallic part is about 5mm.
Note: All connection wires needs to be flexible cable.
Wiring diagram of AC120V/230V power input.
In some cases, you may have some loads just only can be used on the voltage of DC24V and hope that it still can be controlled by the Nano Switch, so please
refer to the following diagram to achieve this:
Note: The ?IN? terminal should be connected to the ?-? of DC 24V input.
Wiring diagram of DC24V power input.
Since the Nano Switch also supports the DC24V power input, so you can use it to control the loads that powered by DC24V.