Make sure that, when the knob is turned rapidly high
to low, the flame does not go out.
In the event of a malfunction on appliances with the
security device (thermocouple) when the gas supply
is set at minimum, increase the minimum supply levels
using the regulator screw in Fig. A - B.
Once the adjustment has been made, apply sealing wax,
or a suitable substitute, to the old seals on the by-pass.
20