Ariston TCL73XS Руководство по эксплуатации и установке - Страница 14
Просмотреть онлайн или скачать pdf Руководство по эксплуатации и установке для Сушилка Ariston TCL73XS. Ariston TCL73XS 44 страницы.
Также для Ariston TCL73XS: Буклет по уходу, использованию и установке (44 страниц)
Installation Instructions
Read these instructions with care.
EN
These instructions are provided for use by qualified
installers, in addition the installation must comply with:
In the United States, in accordance with the
National Electric Code ANSI/NFPA70 - latest edition
and any State, Municipal or local codes.
In Canada, in accordance with the Canadian
Electric Code C22.1 - latest edition and any
Provincial, Municipal or local codes.
Electrical
The dryer comes with a four-wire power supply cord
fitted with a 14-30P (plug), a receptacle should be
fitted in a location accessible after the dryer is
installed. The four wire dryer wire cord assembly fitted
must be used when the appliance is installed in a
location where grounding through the neutral is
prohibited. Grounding through the neutral is prohibited
for; new branch-circuit installations; mobile homes,
recreational vehicles and areas were local codes do
not allow grounding through the neutral conductor.
If a 10-30R (receptacle) is installed a locally obtained
3 wire dryer cord kit minimum ratings 240V, 30A, 95C
and marked for clothes dryers (ring terminals) should
be fitted
To fit a 10-30P dryer cord assembly follow the steps
below:
1. Make sure the dryer is not plugged into a power
outlet.
2. Remove the cover from the cable junction box
located on the rear of the dryer.
3. Remove Green link wire from ground terminal.
4. Loosen the nut securing the cable bush, disconnect
and discard the existing cable and bush.
5. Fit one end of the Green link to the ground terminal
using washer and nut. Position the link wire to the
Neutral terminal (N), but do not fit securing screw at
this stage.
6. Follow any instructions provided with the kit and fit
the cable using the strain relief supplied with the
kit, do not fully tighten the strain relief at this stage.
14
Green link wire.
7. Connect the L1, N and L2
wires.
On flat cords the center wire
is the Neutral conductor, fit to
the terminal marked 'N'.
On round cords the Green or
White conductor should be
fitted to the terminal marked 'N'.
8. Fully tighten the terminal block screws and ground
connection nut, position the cord, finally fully tighten
the strain relief.
9. Refit the cover to the box.
Grounding
Some local codes may require a separate ground. In
such cases the required ground wire, clamp and
screw must be purchased separately.
NEVER ground the dryer to plastic plumbing lines,
gas lines or water pipes.
NOTE: IF IN DOUBT ABOUT ANY OF THE ABOVE
CONSULT A QUALIFIED ELECTRICIAN.
Where to put your dryer
Check local codes before choosing a location. Some
codes do not permit installation in a garage, closet,
mobile home or bedroom.
DO NOT install the dryer in an area where gasoline or
other inflammable materials are kept or stored.
When operating the dryer, there has to be adequate
ventilation. Make sure you put the dryer in an
environment that is not damp and has proper air
circulation throughout. Airflow around the dryer is
essential to condense the water produced during
washing, the dryer will not operate sufficiently in an
enclosed space or cupboard. If installed in a closet
we recommend that you leave the door open when
the dryer is in use.
! If using the dryer in a small room or cold room some
condensation could be experienced.