If the refrigerator door
remains open for more than
2 minutes
Alarm activated
If the Electronic Control –
PCB is working properly.
Food on the
If vegetable tray humidity
vegetable tray
regulator is closed.
sweating.
If the evaporator is blocked
by ice.
Does not Chill /
Chills not much
The Sealed system
in
operation, as
the Freezer
leakage or restriction on the
system, compressor
compressing, fluid charge
and others.
If any Alarm, was activated
If the Electronic Control –
PCB is working properly.
If the doors are closing
properly.
Internal
refrigerator
If the temperature set is on
sweating.
the proper position.
If still hot, unpacked or
uncovered food was stored.
External temperature and
relative humidity are high.
If the minimum embedding
distances were observed.
External
sweating
If there is heat
souRefrigerator Fan Motore
(stove, heaters) near the
product or direct sunshine
on it.
Gasket bad sealing.
If any wiring cables are
chocking with the cabinet
liner or fan motor
If the product is unleveled.
Fan motor noise.
Noise.
Noise when compressor is
turned on/off.
Noises during the
defrosting.
Difficulty to open
If the vacuum valve is
the doors.
blocked.
If the product is unleveled.
Difficulty to close
If utensils and internal
the doors.
portions are properly
positioned.
Advise the consumer to
close the refrigerator door
and explain the Open Door
Alarm system to her/ him,
according the Alarm system
item on this Manual.
Check if all interface
components are OK, if not,
replace the failure
component, if yes, replace
the PCB.
Adjust the humidity
regulator to a more open
position.
Check the defrost system:
The Defrost Sensor
operation and if it
is improperly positioned
The Defrost Heater is
opened or improperly
positioned The Electronic
Control – PCB.
Check if the Chute or
Defrosting Drain is blocked.
Replaced the failure
component and do the
reoperation system.
Check orientation done on
this Manual, regarding
respective Alarm code.
Check if all interface
components are OK, if not,
replace the failure
component, if yes, replace
the PCB.
-level the product
-check the gasket
-check the hinges
adjustment.
Place the selection on the
proper adjust and advise
the consumer.
Advise the consumer.
Advise the consumer that
the external sweating is
normal in these situations.
Advise the consumer to
observe the minimum
embedding distances (10
cm on the top and 3cm on
the sides).
Advise the consumer to
detach or remove such heat
souRefrigerator Fan
Motores.
Adjust or replace it.
Put them in the correct
position and if is necessary
use some adhesive tape to
fix it
Level it and advise the
consumer.
Advise the consumer about
no-frost system.
Advise the consumer that
this is normal.
Check capillary absorber
tape
Advise the consumer that
this is normal.
Unblock it and advise the
consumer.
Level it and advise the
consumer.
Position them properly and
advise the consumer.
15