Whirlpool 3395314 Руководство по установке - Страница 5
Просмотреть онлайн или скачать pdf Руководство по установке для Сушилка Whirlpool 3395314. Whirlpool 3395314 12 страниц. Coin-operated stacked dryer
Exhaust
requirements
Fire/Health Hazard
l
Do Not use non-metal, flexible
duct.
l
Do Not use metal duct smaller
than four Inches In diameter.
l
Do Not use exhaust hoods wlth
metal latches.
B Check that exhaust system Is not
longer than speclfled. Exhaust
system longer than speclfled will:
- Accumulate
Ilnt.
- Shorten the life of the dryer.
- Reduce the petformance,
resulting In longer drying times
and Increased energy usage.
Iallure to
kii0w
speclflcatlons
may
'esult In a IIre.
b Do Not exhaust dryers Into a
chimney. turnace cold alr duct,
attlc or crawl space, or any other
duct used for ventlng.
1 Clean the exhaust system every
other year.
) Do Not Install flexible duct In
enclosed walls, celllngs or floors.
iccumulated
llnt could result In a
Ire or cause molsture damage.
1 Exhaust dryers outslde to prevent
exposure to substances In gas
duels and combustion which may
be harmtul to your health.
. he molsture and llnt Indoors may
cause:
. FIRE HAZARD from llnt collected
In
dryer.
. Molsture damage to woodwork,
turnlture, palnt, wallpaper, carpet,
etc.
n Housecleanlng
problems and
possible health problems.
:allure to tallow these lnstructlons
:ould result In tlre damage or
3ersonal Injury.
Exhaust materials are not
supplied.
Four-Inch metal exhaust duct
is
Four-Inch metal exhaust duct
is
required.
Plan installation
to use the
required.
Plan installation
to use the
fewest number
of elbows
and turns.
fewest number
of elbows
and turns.
Allow as much roo
ossible when
The external exhaust
routed
up, down
requirements
are
length
of the exhaust
exhausted
out the sid
feet with two externa
hood.
Rear exhaust:
The ma
the exhaust
system
If dryers are Installed In a conflned
area
such as a bedroom,
bathroom
or closet, they must be exhausted
to
the outside and provision
must be
made
for enough
air for combustion
and ventilation.
(Check
governing
codes and ordinances.
Also refer to
the 'Recessed
area and closet
installation
instructions,"
Page 8.)
An
exhaust hood
should cap the
exhaust
duct to prevent
exhausted
air from returning
into the dryers. The
outlet hood must be at least 12
inches from the ground
or any object
that may be in the path of the
exhaust.
Four-Inch outlet hood Is preterred.
However,
a 2-l/2-inch
outlet exhaust
hood may be used. (A 2-l/2-inch
outlet creates
greater
back pressure
than other hoods.)
A maln exhaust duct
can be used for
exhausting
a group of dryers. Main
exhaust
duct should be sized to
remove
200 CFM of
air per
dryer.
Large-capacity
lint screens of proper
design may be used in the main
exhaust
duct if checked
and
cleaned
frequently.
The room where
the dryers are located
should have
make-up
air equal
to or greater
than
the CFM of all the dryers in the room.
Thls chart applies only [to Indlvldually
(
/$fya.
*tie
exhausted unlts.
I
4
MAXIMUM
LENGTH OF I-INCH
DIA
TER RIGID METAL DUCT
MAXIMUM
LENGTH OF 4.lNCH
DIAM
ER FLEXIBLE METAL DUCT
available
from your Wb irlpool parts
distributor.
exceed
0.6 inches of
airtlow
-
main
colktorduct
-
Back-draft damper klts
(Part No.
3391910) are available
from your
Whirlpool
dealer
and should be
installed
in each
dryer's exhaust
duct
to prevent
exhausted
air from
returning
into the dryers and to keep
the exhaust
balance
within the main
exhaust
duct. Unobstructed
air
openings
are required.
Each exhaust duct
should enter the
main duct at an angle
pointing
in the
direction
of the airflow.
Ducts
entering
from the opposite
side
should be staggered
to reduce
the
exhausted
air from interfering
with the
other ducts.
The
maxlmum angle
of each duct
entering
the main duct should be no
more than 30".