Whirlpool CEM2743BQ Руководство по установке - Страница 14
Просмотреть онлайн или скачать pdf Руководство по установке для Сушилка Whirlpool CEM2743BQ. Whirlpool CEM2743BQ 48 страниц. Commercial dryer gas or electric
Также для Whirlpool CEM2743BQ: Руководство по установке (48 страниц)
DRYER VENTING REQUIREMENTS
Vent Hoods
4" (102 mm) Diameter Exhaust Hoods
Box Hood
Louvered Hood
Vent System Length
Maximum Vent Length/Vent Connection
Maximum length of vent system depends upon the type of vent
used, number of elbows, and type of exhaust hood.
Vent System Chart (Rigid Metal Vent)
No. of
Box and
90˚ Turns
Louvered Hood
0
64 ft. (19.5 m)
1
54 ft. (16.5 m)
2
44 ft. (13.4 m)
3
35 ft. (10.7 m)
4
27 ft. (8.2 m)
For vent systems not covered by the vent specification chart,
see your parts distributor.
Provision must be made for enough air for combustion and
ventilation. (Check governing codes and ordinances.) See
"Recessed Area and Closet Installation Instructions" in the
"Location Requirements" sections.
A 4" (102 mm) outlet hood is preferred. However, a 2
(64 mm) outlet exhaust hood may be used. A 2
outlet creates greater back pressure than other hood types.
For permanent installation, a stationary vent system is required.
Connect Vent
1. If connecting to existing vent, make sure the vent is clean.
2. Using a 4" (102 mm) clamp, connect vent to exhaust outlet
in dryer.
NOTE: Do not remove vent collar.
14
Angled Hood
Angled
Hood
58 ft. (17.7 m)
48 ft. (14.6 m)
38 ft. (11.6 m)
29 ft. (8.8 m)
21 ft. (6.4 m)
⁄
"
1
2
⁄
" (64 mm)
1
2
Vent Collar
Exhaust hood must be at least 12" (305 mm) from the ground
or any object that may be in the path of the exhaust (such as
flowers, rocks, bushes, or snow).
3. Tighten hose clamp with Phillips screwdriver.
4. Make sure the vent is secured to exhaust hood with
a 4" (102 mm) clamp.
5. Move dryer into final position. Do not crush or kink vent.
Make sure dryer is level.
12" min.
(305 mm)