Whirlpool WGD5700V - 7.0 Cu Ft Размеры и информация по установке
Просмотреть онлайн или скачать pdf Размеры и информация по установке для Сушилка Whirlpool WGD5700V - 7.0 Cu Ft. Whirlpool WGD5700V - 7.0 Cu Ft 1 страница. 29" and 27" gas dryer
Также для Whirlpool WGD5700V - 7.0 Cu Ft: Размеры и информация по установке (1 страниц), Инструкции пользователя (24 страниц), Размеры и установка (2 страниц), Размеры и информация по установке (1 страниц)
®
29" (73.7 cm) Gas Dryer
PRODUCT MODEL NUMBERS
WGD5000V
WGD5700V
WGD5100V
WGD5790V
WGD5200V
Gas supply: Dryer is equipped for use with
Natural gas. Dryer can be converted to L.P. gas.
When rigid pipe is used it should be 1/2" IPS. When
acceptable to the gas supplier and local codes, 3/8"
approved aluminum or copper tubing may be used
for lengths under 20 ft (6.1 m). For lengths more
than 20 ft (6.1 m), larger tubing and a different size
adapter fitting should be used. Pipe-joint compounds
resistant to the action of L.P. gas must be used. Do
not use TEFLON
®
tape. If local codes permit, it is
†
recommended that new flexible metal tubing, design-
certified by CSA, be used for connecting the
appliance to the rigid gas supply line. (The gas pipe
which extends through the lower rear of the
appliance has 3/8" male pipe thread.) An individual
manual shutoff valve must be installed within 6 ft
(1.8 m) of the dryer in accordance with the National
Fuel Gas Code ANSI Z223.1.
Electrical: A 120-volt, 60-Hz, AC-only, 15- or
20-amp, fused electrical supply is required. A time-
delay fuse or circuit breaker is recommended. It is
recommended that a separate circuit serving only
this dryer be provided.
Exhaust venting: Exhaust your dryer to the outside.
4" (10.2 cm) diameter heavy metal exhaust vent and
clamps must be used. DURASAFE™ venting products
are recommended. For best drying performance, rigid
metal vents are recommended. Flexible metal vents are
acceptable only if accessible for cleaning. Do NOT use
plastic or metal foil vent. Exhaust outlet hood must be
at least 12" (30.4 cm) from the ground or any object
that may be in the path of the exhaust.
†®TEFLON is a registered trademark of E.I. Du Pont De
Nemours and Company.
EXHAUST VENTING
Box hood style
4"
(10.2 cm)
4"
(10.2 cm)
NOTE: Side and bottom exhaust installations have a
90º turn inside the dryer. To determine maximum
exhaust length, add one 90º turn to the chart.
Vent Length Chart
Number of
Type of
90° turns
vent
or elbows
0
Rigid metal
64 ft (20 m)
Flexible metal
36 ft (11 m)
1
Rigid metal
54 ft (16.5 m)
31 ft (9.4 m)
Flexible metal
2
Rigid metal
44 ft (13.4 m)
Flexible metal
27 ft (8.2 m)
3
Rigid metal
35 ft (10.7 m)
25 ft (7.6 m)
Flexible metal
4
Rigid metal
27 ft (8.2 m)
Flexible metal
23 ft (7 m)
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
PRODUCT DIMENSIONS
A. Small Opening
Side-Swing Door
B. Large Opening
Side-Swing Door
C. Wide Opening
Side-Swing Door
D. Wide Opening
Hamper Door
*Most installations require a minimum 5" (12.7 cm) clearance
behind the dryer for the exhaust vent with elbow.
RECESSED AREA AND CLOSET INSTALLATION
For closet installation
with a door, minimum
ventilation openings in
the top and bottom of
the door are required.
Louvered doors with
equivalent ventilation
openings are acceptable.
4"
(10.2 cm)
2.5"
(6.4 cm)
Angled hood style
Box or
Angled
Louvered
hoods
hoods
58 ft (17.7 m)
28 ft (8.5 m)
48 ft (14.6 m)
23 ft (7 m)
38 ft (11.6 m)
19 ft (5.8 m)
29 ft (8.8 m)
17 ft (5.2 m)
21 ft (6.4 m)
15 ft (4.6 m)
A
C
18"*
(45.7 cm)
29"
1"
(2.5 cm)
(73.66 cm)
A
A. Recessed area
A R
B. Side view - closet or confined area
C. Closet door with vents
1. Select the route that will provide the straightest and most direct path outdoors. Plan
the installation to use the fewest number of elbows and turns. When using elbows or
making turns, allow as much room as possible. Bend vent gradually to avoid kinking.
Avoid 90° turns.
2. Determine vent length.
The maximum length of the exhaust system depends upon:
• The type of vent (rigid metal or flexible metal).
• The number of elbows used.
• Type of hood.
See the exhaust vent length chart that matches your hood type for the maximum vent
lengths you can use.
3. Determine the number of elbows you will need.
IMPORTANT: Do not use vent runs longer than specified in the Vent Length Chart.
In the column listing the type of metal vent you are using (rigid metal or flexible metal),
find the maximum length of metal vent on the same line as the number of elbows.
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
B
D
14" max.*
2
48 in.
*
(35.6 cm)
2
(310 cm )
2
*
24 in.
2
(155 cm )
1"
27¾"
5"*
1"*
(2.5 cm)
(70.5 cm)
(12.7 cm)
(2.5 cm)
B
d
3"*
(7.6 cm)
3"*
(7.6 cm)
C
*Required spacing
Ref. W10150630
09-19-08