Optional exhaust installations
This dryer can be converted to exhaust out the right side, left
side, or through the bottom. Contact your local dealer to have the
dryer converted.
Fire Hazard
Cover unused exhaust
holes with one of the
following
kits:
279818 (white)
279820 (black)
279925 (biscuit)
279969 (pewter)
280171 (diamond
dust)
W10152954
(new aspen)
W10152955
(tuscan chestnut)
Contact your local dealer,
Failure to follow
these instructions can result in death,
fire, electrical
shock, or serious injury.
A
B
C
A. Standard rear offset exhaust installation
B. Left or right side exhaust installation
C. Bottom exhaust installation (not an option
with pedestal installations)
Alternate
installations for close clearances
Venting systems come in many varieties. Select the type best for
your installation. Two close-clearance
installations are shown,
Refer to the manufacturer's
instructions,
V,'Y
=
l/
A
B
A. Over-the-top
installation (also available with one
offset elbow)
B. Periscope installation
NOTE: The following kits for close clearance alternate
installations are available for purchase. To order, please see the
"Assistance
or Service" section,
•
Over-the-Top
Installation:
Part Number 4396028
•
Periscope Installation (For use with dryer vent to wall vent
mismatch):
Part Number 4396037 - 0" (0 cm) to 18" (45,72 cm) mismatch
Part Number 4396011 - 18" (45.72 cm) to 29" (73,66 cm)
mismatch
Part Number 4396014 - 29" (73.66 cm) to 50" (127 cm)
mismatch
Special
provisions for mobile home installations
The exhaust vent must be securely fastened to a noncombustible
portion of the mobile home structure and must not terminate
beneath the mobile home, Terminate the exhaust vent outside,
Determine
vent path
•
Select the route that will provide the straightest and most
direct path outdoors.
•
Plan the installation to use the fewest number of elbows and
turns.
•
When using elbows or making turns, allow as much room as
possible.
•
Bend vent gradually to avoid kinking.
•
Use the fewest 90 ° turns possible.
Determine
vent length and elbows
needed for best
drying performance
•
Use the following Vent system chart to determine type of vent
material and hood combinations
acceptable to use.
NOTE: Do not use vent runs longer than those specified in
the Vent system chart. Exhaust systems longer than those
specified will:
•
Shorten the life of the dryer.
•
Reduce performance, resulting in longer drying times and
increased energy usage.
The Vent system chart provides venting requirements that will
help to achieve the best drying performance.