Whirlpool RH2000 Series Инструкции по установке - Страница 3
Просмотреть онлайн или скачать pdf Инструкции по установке для Вентиляционная вытяжка Whirlpool RH2000 Series. Whirlpool RH2000 Series 5 страниц. 30" vented custom series range hood
Также для Whirlpool RH2000 Series: Инструкции по установке (5 страниц), Инструкции по установке (5 страниц), Инструкция по установке и руководство по эксплуатации и уходу (7 страниц)
Venting
system must terminate
to the
outside,
Do not terminate
the vent in an attic or
other enclosed
space,
Do not use four-inch
laundry-type
wall caps,
Do not use plastic vent,
Vent system needed
for installation
is not
included,
Backdraft
damper
supplied
with
product
must be used. If roof or wall cap
has a damper,
do not use damper
supplied
with hood, Use metam vent onmy. Rigid metam
vent is recommended.
This range hood can be vented
to the
outside ONLY.
Determine
which outside venting
method
needs to be used,
The length
of the vent system and number
of elbows should be kept to a minimum
to
provide
efficient
performance,
The size of
the vent system should be uniform,
Do Not
install two elbows together,
Use duct tape
to seal all joints in vent system, Vent system
can terminate
either through
the roof or
wall, Use caulking
to seal exterior wall or
roof opening
around
exhaust
hood,
For the
most efficient
and quiet operation,
it is
recommended
that the range be vented
vertically
through
the roof through
7" round
vent system,
Figures 1-2 show common
venting
methods
and what types of materials
are needed,
Vertical Roof Venting
7" round
through
the _
_
roof
damper
located
as for from hood
as possible
66 '_
Figure ]
roof cap
roof
7" rain.
round vent
Recommended
vent system length
Maximum
length of vent system is 26 feet,
For best performance,
use no more than
three 90 ° elbows,
To calculate
the length of
system you need, add the equivalent
feet
for each
vent system piece
used in the
system, See the following
example,
7" vent s' rstem
90 ° eJbows
_6
ft,
2ft.
_L
Maximum
length
= 26 feet
1 -- transition
= 4,5 ft,
2--
90 ° elbows
= 10
ft,
8 feet straight
= 8
ft,
3-1/4"
x 10"
tO7"
1 -- wall cap
= 0
ft,
transition
Length of 7" system
= 22,5 ft,
Recommended
standard
fittings
3=114" x 16" to
3-114" x 16" to 7"
7" to 3=1t4" x 16"
7" = 4.6 ft.
90 ° elbow = 6 ft.
96 ° e_bow = 9 ft.
90 ° elbow=
7" to 3ot14"
46 ° elbow=
7" wall cap
6 ft,
x 16" = 1 ft.
2.6 ft,
= 6 ft.
Panel B
12,
t3,
correspond
fo sfeps.
Now
starL..
With range hood in kitchen.
Slide cardboard
or hardboard
under range
before
moving
range across floor to
prevent
damaging
floor covering,
Cover countertop,
cooktop
or setqn range
with a thick, protective
covering
to prevent
damaging
countertop.
Disconnect
and move freestanding
m range from cabinet
opening
to
provide
easier access to upper cabinet
and
rear wall, Put a thick, protective
covering
over cooktop,
set-in range or countertop
to
protect
from damage
or dirt,
Determine
which venting
method
m (roof or wall venting)
you need to
use,
.,wiring
knockouts
m
Remove
knockout
from the wiring opening
(top or rear) to be used,
terminal
box
cover
If your model
does NOT have a factory
installed
power
cord,
remove
terminal
box cover from range hood,
Excessive
Weight Hazard
Use two or more people to move and
install range hood.
Failure to follow this instruction can
result in back or other injury,.
keyhole
slot
_
front of hood
Lift the range hood into final
position and center,
Mark on the
underside
of cabinet
the location
of the
four keyhole
mounting
slots, Set range hood
aside on a protected
surface,
I
L
centerline
m
Determine
and clearly mark a vertical
centerline
on the wall and cabinet
in the
area the vent opening
will be made,
To wire through
top, mark a line 7-1/2" from
the right of the centerline
on the underside
of the cabinet,
Mark the point on this line
that is 2" from back wall, Drill a 1-1/4"
diameter
hole through
the cabinet
at this
point, Note: If a cord-connection
kit is used,
drill a 1-5/8" diameter
hole,
/'1
I
f
'll
I
L
65- l/4"
do floor)
cenferline
To wire through
rear, mark a line 7-1/2" from
the right of the centerline
on the wall, Mark
the point on this line that is 65-1/4" from the
floor (or 3/4" from underside
of cabinet),
Drill
a 1-1/4" diameter
hole through
wall at this
point,