Whirlpool UXT2030ADB0 Инструкции по установке и руководство по эксплуатации и уходу - Страница 4

Просмотреть онлайн или скачать pdf Инструкции по установке и руководство по эксплуатации и уходу для Вентиляционная вытяжка Whirlpool UXT2030ADB0. Whirlpool UXT2030ADB0 28 страниц. 30" (76.2 cm) range hood

Whirlpool UXT2030ADB0 Инструкции по установке и руководство по эксплуатации и уходу
Product
Dimensions
2"
-"_
6%o" (16.7cm)
415/16"
(12.5 cm)
291%6" (76.0cm)
1 "
(2.5 crn)
18%"
cm)
Venting
System
Venting Methods
NOTES:
Flexible vent is not recommended.
Flexible vent creates both
back pressure and air turbulence that greatly reduce
performance.
The vent system is optional for this model.
Vent system can terminate either through the roof or wall. Use 7"
(17.8 cm) or larger round vent with a maximum length of 50 ft
(15.2 m) for vent system.
Top Venting
Wall Venting
Installation Clearances
E
A. 18" (45.7 cm) minimum distance from electric cooking surface.
24" (61.0 cm) minimum distance from gas cooking surface.
30" (76.2 cm) suggested maximum above the cooking surface.
B. 18" (45.7 cm) minimum clearance - upper cabinet to countertop.
C. 30" (76.2 cm) minimum cabinet opening width.
D. 12" (30.5 cm) cabinet depth.
E. 36" (91.4 cm) base cabinet height.
B
A. 7" (17.8 cm) round vent
through roof
(purchased separately).
B. Roof cap with damper
(purchased separately)
A. 7" (17.8 cm) round vent out
the top and through the wall
(purchased separately).
B. Wall cap with damper
(purchased separately)
Cold Weather
Installations
An additional back draft damper should be installed to minimize
backward cold air flow and a thermal break should be installed to
minimize conduction
of outside temperatures
as part of the vent
system. The damper should be on the cold air side of the thermal
break.
The break should be as close as possible to where the vent
system enters the heated portion of the house.
Makeup
Air
Local building codes may require the use of makeup air systems
when using ventilation systems greater than specified CFM of air
movement. The specified CFM varies from locale to locale.
Consult your HVAC professional for specific requirements in your
area.
Venting Requirements
Vent system must terminate to the outdoors.
Do not terminate the vent system in an attic or other enclosed
area.
Do not use a 4" (10.2 cm) laundry-type wall cap.
Use 7" (17.8 cm) round metal vent. Rigid metal vent is
recommended.
Plastic or metal foil vent is not recommended.
The length of vent system and number of elbows should be
kept to a minimum to provide efficient performance.