Appendix B - Connector Wiring

HotPort Outdoor Node Ethernet Transition Cable Pin Descriptions

Power Connector Pin Descriptions

Figure 13 shows the pinout of the power connectors used to supply power to Series 6100 nodes (left) and Series 6200 nodes (right). Each
view is of the cable connector, as viewed end-on.
If you wish to construct a cable to supply power to a Series 6200 node with a Series 6100 node indoor power supply, you can do so by wiring
as shown in Figure 13. Likewise, other cables can be constructed for custom applications, as long as the wiring shown is followed.
In all cases, DC power to a HotPort node must be 15 VDC ±15%, up to 3A. Series 6200 HotPort nodes can provide PoE-compliant 48 VDC
power to other devices.
2
1
Male - End View
Connect to Power
Supply
February 2007
Table . Circular, Watertight IP66-Rated Connector and Port Pin Descriptions
Connector Pin #
1
White/Orange
2
Orange
3
White/Green
4
Blue
5
White/Blue
6
Green
7
White/Brown
8
Brown
Drain Wire
Drain Wire
Table . RJ- Connector Pin Descriptions
Pin #
1
2
3
4
5
6
7
8
Figure 1. Power Transition Cable
brown
Pin 1
blue
3
Pin 2
4
black
Pin 3
white
Pin 4
Wire Color
Port Pin #
1
2
3
4
5
6
7
8
9
10
Signal
Description
TXD+
TX Data 10 BaseT/100 BaseTX
TXD-
TX Data 10 BaseT/100 BaseTX
RXD+
RX Data 10 BaseT/100 BaseTX
PoE+
+48 VDC PoE Power
PoE+
+48 VDC PoE Power
RXD-
RX Data 10 BaseT/100BaseTX
PoE-
-48 VDC PoE Power
PoE-
-48 VDC PoE Power
power
ground/drain
9
10
7
8
5
6
3
4
1
2
Pin 4
3
4
2
6
5
1
Pin 3
Female - End View
Connect to 6200
Series HotPort
Firetide Instant Mesh Networks 1