OPERATION
(CONT'D)
PRACTICAL
TIPS
To avoid window condensation:
• It is not necessary to
change the humidity control
every day. Monitor the
average weekly
temperature or experiment
with various settings until
you find a level that is
comfortable for you. Adjust
the control when needed.
NOTE:
A dehumidistat is ideal for
use in energy efficient
houses where indoor
humidity (during the
heating season) is higher
than outdoor levels. High
humidity is a major cause
of structure damage and
IAQ problems such as mold
and mildew.
PRACTICAL
TIPS
NOTE:
When an Intellitek control
is installed, the rocker
switch located on the right
hand side of the HRV will
be automatically
deactivated giving the user
complete control from
wherever he/she wishes to
mount the control pad.
NOTE:
The override speed cannot
be set at a fan speed lower
or equal to the normal
operating fan speed. For
example, if the unit is
normally operating at a
medium fan speed, the
override fan speed will be
automatically set to high.
NOTE:
5MR model, changing the
override speed will change
default override speed for
other external controls.
EXAMPLES:
If on the 5MR control, you
have set the override
control at medium, and
you start an external
remote control (15 min.
timer), the unit will run at
medium speed for 15 min.
13

OPTIONAL REMOTE CONTROLS

Dehumidistat I - The wall mount dehumidistat monitors the humidity level in
2 wire
installation
the area it is installed. When the humidity level rises above the desired set-
point, the HRV will activate to high speed/override mode. Once the humidity
level returns to desired condition, the unit will return to the normal mode.
Dehumidistat II - The wall mount dehumidistat II offers the same features of
4 wire
installation
the dehumidistat I plus additional off/on control for the HRV. Dial illuminates
when in override mode.
RTS 3 - The RTS 3 is designed to provide an intermittent boost to the Heat/Energy
3 wire
installation
recovery ventilator. Depressing the fan control button will energize the HRV/ERV
system into high speed from a low or standby mode. The ventilator can be set to
continue on high for 20, 40, or 60 minutes by pressing the control button one, two
or three times. Pressing the button a fourth time will cancel the timing function.
EDF 1 - The EDF 1 is designed to provide 3 modes of operation to the Heat/Energy
2 wire
recovery ventilator. Pressing the "Push" button once initiates the unit to run at a
installation
continuous low speed of operation (green). Depressing the button twice allows the
ventilator to run for 20 minutes and then turns off for 40 minutes (yellow). Touch
the button a third time and the system will run continuous on high (red). The ven-
tilation system will stay on the last function selected until it is changed.
15-min Timer - The 15-minute remote timer is typically installed in areas
2 wire
installation
where contaminated such as moisture and odors, are produced. Simply push
the button and the HRV will activate to high speed for 15 minutes. Up to 5
electronic timers can be installed throughout the building at a distance of up
to 500 feet (152 meters) from the HRV.
OPTIONAL INTELLITEK CONTROL
DIGITAL DISPLAY
Shows Indoor Humidity Level
This control will not read
below 29% RH
OVERRIDE TIMER
When pressed, unit
will provide high
speed
ventilation
for one 15,
30 or 60 minute
period.
MAINTENANCE LIGHT
Light comes on when
it's time to clean
unit.
POWER
On/Off and Reset
MODES
MODE SPEED
Select Intermittent,
Set Unit to Low,
Recirculation or
Medium or High
Continuous
Speed
Ventilation Modes
DEHUMIDISTAT CONTROL
(see description on top of this page)
4 1/2"
(114 mm)
CYCLE CONTROL
Set unit to cycle on
15, 20, or 30 min-
utes every hour
* All controls are low voltage. 18 to 24
gauge wire is recommended.
5MR
INTELLITEK
MULTI-FUNCTION
WALL CONTROL
Control multiple func-
tions of your
Powrmatic HRV with
one slimline wall con-
trol. Two wire connec-
tion simplifies installa-
tion. Use one EDF5 per
PHRVR installed.
5 1/8"
(130 mm)
Width = 4 1/2" (110mm)
Height = 5 1/8" (130mm)
Thickness = 5/8" (15mm)
OVERRIDE SPEED
CONTROL
Push to select
override speed of
unit.