The ALDEN SPS regulators have been designed based on high technology knowledge. Compatible with any type of
battery, these regulators are most adapted for leisure vehicles. Robust and reliable, they are guaranteed two years.
Special functions:
- 'Quick' function : This function stops the battery from over loading. The charge will start again when the battery load
decreases.
- Controlled use : Thanks to continuous measurments, the inner circuits checks the voltage of the batteries. The regulators
deliver a pre-definded voltage depending on various parameters over a certain period of time and will then maintain the
load of the battery at this level: this will avoid sulphatation which could damage and weaken the battery.
- Filters : Inner filters allow other sources to load at the same time.
- Indicator leds : Two leds indicate the charge and the level of charge. These leds can be switched on at the same time,
which means that the battery is almost full but continues to load.
As soon as there is enough sunlight, the battery starts to load. The green light comes on. The inner circuits chooses
the appropriate voltage. In some cases, it lets the tension go up to 14.2 Volts (limits gas formation). It authorizes a
quicker load as well as an improvement of the battery capacity, while decreasing sulphating. Once this is done,
the tension delivered to the battery is kept at a «normal» charge of 13.8 Volts. If the charge decreases a little,
recharging will be done «normally». On the other hand, if the discharge is more important or if the tension goes
under 11.6 Volts, the battery will be reloaded up to 14.2 Volts. We advise the installation of Accuprotect® to avoid
deep discharges.
- Connect the cables from the panel to the input of the regulator.
Warning
: the cables from the panel must never touch each other.
- If you have an installation with several panels, connect them in parallel.
- Use 2.5 to 5 mm
- Install the regulator as close as possible to the battery.
- Using a 5 Amp. fuse, connect the +12V output directly to the + of the cell-battery.
- Connect the '-' output directly to the earth of the vehicle.
Temperature sensor (optional) :
Connect the cables of the Temp. Sensor to the corresponding inputs (
Solar display (optional) :
Connect the Solar Display to the corresponding input (
Warning
: Do not connect whilst under voltage.
Warning
: you must install a 7,5 Amp. fuse on the '+' line between the regulator and the cell-battery.
Global information