Yamaha DME32 Руководство по настройке оборудования - Страница 7

Просмотреть онлайн или скачать pdf Руководство по настройке оборудования для Музыкальный инструмент Yamaha DME32. Yamaha DME32 12 страниц. Digital mixing engine
Также для Yamaha DME32: Руководство пользователя (16 страниц)

Yamaha DME32 Руководство по настройке оборудования
AES/EBU
AD824
AD824
AES/EBU
A 16-Channel I/O sytem using AES/EBU transmission. Up to 200 meters of separation between the DME32
In the example above, a split AES/EBU cable is utilized to connect the DME32 to the AD824
and DA824. See the next section for details on creating this cable.
Since no Wordclock signal is sent to the AD824 units in either the AES/EBU or ADAT
connection examples, Wordclock BNC Cables must be run from the DME32 to the AD824.
Please see Chapter 13 (page 227) of the DME32 Owner's Manual for more information on
Wordclocks.
When the wordclock source is changed on the wordclock master device (e.g. AD824 or DME32),
noise may occur from the DA824's analog outputs, especially if an MY8-AT I/O card is installed, so
turn down your power amps, or turn off the DA824 beforehand, otherwise any connected speakers
may be damaged.
BNC Cable (wordclock)
Split AES/EBU Cable
Split AES/EBU Cable
BNC Cable (wordclock)
and the I/O components is possible.
WORDCLOCK SOURCE SETTING CAUTION
AES/EBU
AES/EBU
AES/EBU
DME32
AES/EBU
6
DA824
DA824