Make wiring connections from driver to 1st PCB. Pull lead wires from luminaire
and make splice connections to lead wires from driver. Verify wiring diagram
before connecting.
17
Perform a continuity test before connecting luminaire to power source.
Refer to page 15 for continuity test step by step.
18
Verify driver wire colors from wiring diagram, then connect luminaires to power
source. Drivers used for this product vary. Always confirm wiring diagram from
driver installation instructions before connecting.
19
Verify that all Ceiling Trims are securely leveled, then screw trim to drywall
using countersink screws. Use 1 screw per 2' of trim, rounded up. Drill holes in
ceiling trim if necessary.
20
Apply mud to trims until completely covered and smooth. Allow to dry completely
before painting or sanding. Do not use pre-mixed mud compounds.
21
After all installation steps are complete and lighting is confirmed to be working,
install reflective film to runs.
Note: Follow the steps on page 14 to install reflective film.
CALIFORNIA ACCENT LIGHTING, INC.
2820 E. Gretta Lane, Anaheim, CA 92806
ph. 800.921.CALI (2254) | fx. 714.535.7902 | [email protected] | calilighting.com
© CALI. All rights reserved. CALI reserves the right to make changes or withdraw specifications without prior notice.
Lead Wire
V-Groove Channel
ALS500T-RMW-MI
INSTALLATION INSTRUCTIONS
Mounting (Aircraft Cable Assembly) 3 of 3
1 / 29 / 2021 / Rev 2