Clarke CPR2 Инструкции по эксплуатации и техническому обслуживанию - Страница 6

Просмотреть онлайн или скачать pdf Инструкции по эксплуатации и техническому обслуживанию для Электроинструмент Clarke CPR2. Clarke CPR2 13 страниц. Oil free riveter

• Never exceed the maximum operating pressure for the tool. It is
recommended that air pressure to this tool does not exceed 90 psi
at the tool when running. Higher pressures and unclean air will
shorten the life of the tool due to faster wear and is a possible safety
hazard.

BEFORE USE

WARNING: COMPRESSED AIR CAN BE DANGEROUS. ENSURE THAT YOU
ARE FAMILIAR WITH ALL PRECAUTIONS RELATING TO THE USE OF AIR
COMPRESSORS AND COMPRESSED AIR SUPPLY.
NOTE: Ensure the air supply is turned off.
1. If required, connect an in-line mini oiler to the tool.
• A mini oiler helps to prolong the life of the air tool. Remove the oil fill
screw from the side of the mini oiler and fill with Air-line Oil available
from your CLARKE dealer. Replace the screw before using the tool.
2. If a mini-oiler is not being used, run a few drops of oil through the tool
before use. It can be entered through the air inlet.
3. Connect a suitable hose to the female air inlet
4. Connect the other end of the hose to the air supply.
5. Turn on the air supply and check for air leaks.
• Rectify any found before proceeding.
Your air tool is now ready for use.
You can fit a whip hose with a quick fit coupling if required (available from
your Clarke dealer.).

OPERATION

Before starting work drain any water from the air tank and blow condensation
from the air line. Drain compressor more frequently in hot humid weather.
Note: item Nos refer to parts list, Page 10.
Ensure the correct nosepiece (item 1x) is installed for the size of the rivet
mandril being used, insert the mandril until the rivet buts snugly against the
nosepiece.
Parts & Service: 020 8988 7400 / E-mail: [email protected] or [email protected]
6