Software Setup
Prerequisites
1. Installation CD, memory stick or latest download from website.
2. An IntelliGaze camera unit with appropriate license.
3. A PC with a preferably fresh Windows installation which meets the
hardware requirements.
%
- Have latest Windows patches installed.
- An Internet connection is not required for most installers.
- IntelliGaze provides a common installer for both 32bit and 64bit systems.
- To prevent a re-boot, the camera should be disconnected during setup.
- Updates can be installed over a previous version.
Software Installation
1. Launch setup.exe and follow the instructions until the process
finishes successfully.
2. On a first-time installation, please run the Monitor Calibration
program:
In order to ensure the highest gaze
accuracy over a large working
range, the physical setup of the
system needs to be calibrated
once, when the system is being
integrated.
Most cameras will be attached to
the monitor using a 'VESA mount'.
The interactive sketch will assist
you in locating the requested
measurements.
For later updates, the Monitor Calibration program can be found in
the IntelliGaze program group.
%
In a dual-monitor setup, please make sure the camera is attached to the primary
display!
3. Plug in the camera and wait until a Windows message confirms the
installation of 'alea technologies drivers'.
The device manager now lists the camera driver in the USB section,
I
additionally the Internal Camera Status LED (
) turns yellow.
4. Start IntelliGaze, and position yourself centered about 60cm (2ft.)
from the camera.
Open the Operation Center and verify the proper functioning by
checking the Tracking Status Monitor: stable green 'smiley' and no
error messages. The 'smiley' should follow your head movements
without significant delay or stutter.
%
The Tracking Status Monitor reacts on touch and will provide more details or
options in case of problems.
5. The basic IntelliGaze system has now been installed.
Setting System Preferences for Desktop Control
Start IntelliGaze and open the preferences dialog (i.e. Ctrl-F11 or via OC).
● General - Select your language and ensure that the camera license
matches your requirements.
● Integrated Keyboard - Select your preferred keyboard layout(s).
● Input - adapt the preferred input option(s), i.e. dwell or blink click
or/and switches. This will be the 'triggers' which can be used in
application profiles.
%
If Windows should provide gaze input directly after boot-up, you will have to add
IntelliGaze to the Startup folder.
Configuring the Service Mode (optional)
Close IntelliGaze and start the IntelliGaze Service program to adjust the
parameters if needed:
● Win7: Enable and set up touch screen input. (Automatic in Win8
and Win10).
● Optional: Disable automatic search for software updates.
Safety & Compliance
The IntelliGaze™ IG30NT systems has been certified for general office use as in the class of
information and telecommunication devices. The system will meet or exceed the required
standard according to CE and FCC regulations.
Safety of the Infrared Illumination
The camera system contains LED sources that emit light in the near infrared (NIR) spectrum. The
light emission levels have been measured and calculated to comply with the European laser
safety standard EN60825-1. The standards contain test procedures to verify that the emitted
light will cause no thermal injury to the eye of a person being exposed to the light. The product
is classified as a Class 1 LED product and complies with the standards for long-time exposure.
Exposure varies with the chosen frame-rate and working distance. For comparison reason: the
user will be exposed to about 200mW/cm² at 40Hz tracking rate in the suggested operating
distance of 60cm / 2ft..
Magnetic Field Hazard
The CAM30NT unit contains small magnets. Magnetic fields may interfere with the function of
cardiac pacemakers and implantable defibrillators. As a general rule, please maintain a minimum
distance of 10cm /4 in. between the frontal part of the device and any implanted, electronic
device.
Epilepsia / Photosensitive Seizure Warning
A very small percentage of people may experience a seizure when exposed to certain visual
images, including flashing lights or patterns that may appear in video games. Even people who
have no history of seizures or epilepsy may have an undiagnosed condition that can cause these
photosensitive epileptic seizures while using a gaze interaction device on a computer screen.
These seizures may have a variety of symptoms, including lightheadedness, altered vision, eye
or face twitching, jerking or shaking of arms or legs, disorientation, confusion, or momentary
loss of awareness. Seizures may also cause loss of consciousness or convulsions that can lead to
injury from falling down or striking nearby objects. Immediately stop while using a gaze
interaction device on a computer screen and consult a doctor if you experience any of these
symptoms. Parents should watch for or ask their children about the above symptoms - children
and teenagers are more likely than adults to experience these seizures.The risk of photosensitive
epileptic seizures may be reduced by taking the following precautions:
● Using a gaze interaction device on a computer screen only in a well-lit room.
● Do not use a gaze interaction device on a computer screen if you are drowsy or fatigued.
● If you or any of your relatives have a history of seizures or epilepsy, consult a doctor before
playing.
Mounting Warning
The camera should be mounted according to manufacturer or authorized system integrator
instructions. alea technologies is not liable for damage or injuries due to a dropped or tipping
over device . The mounting of an alea technologies product is done entirely at the user's own
risk.
Emergency Situations
Be aware that due to the possible risk of failure, the IntelliGaze system should not be relied
upon exclusively as an audio communications or an environmental control device. In emergen-
cies, as well as in dangerous, or other wise sensitive situations , do not solely rely on the device
for communication.
Do Not Open the Camera Device
There are no user serviceable parts inside. Non-compliance will result in loss of Warranty!
Hot Key
Function
Ctrl-A
Show Application Center (Safe Mode only)
Ctrl-F5
Start calibration
Show Operation Center
Ctrl-F1 /
Ctrl-F11
Enter preferences menu - Equiv. tray icon.
Space
Accept calibration point manually
Toggle mouse cursor control on/off
PAUSE
Ctrl-D
Screen video recording, with gaze on/off
Ctrl-F12
Toggle Demo Mode on/off
Ctrl-
/
Show side menus
Show integrated keyboard
Ctrl-
Ctrl-Q
Quit IntelliGaze
Copyright © alea technologies gmbh, 2015 - All rights reserved.
IntelliGaze™ and BlickFang™ are trademarks of alea technologies gmbh. Other products,
trademarks or registered trademarks are the property of their respective owners.
™
IG30NT Gaze Communication System
Quick Start Guide
3-Dez-15
Hardware Setup
Prerequisites
PC connection
A free USB 2 or 3 port, preferably directly on the computer.
Monitor Size
IntelliGaze can track most users accu-
rately on monitors up to 22". The camera
should be mounted as closely as possible
to the screen area to achieve best results.
A VESA mount is desirable.
Monitor Arm / Desktop Stand
It is highly recommended to use a monitor arm or adaptable desktop stand
to provide flexibility when positioning the system.
Camera Hardware - CAM30NT
7
7
8
3
4
2
1
9
5 6
4
Mini-USB2 connector
Status LED - Green: OK.
Cable lock
Aux. Mounting threads:
M3, max. 8mm Depth.
8mm pin-mount
Internal Camera Status LED
Yellow: OK
Pin-lock screw.
Device label.
Auxiliary power supply. Use
only certified adapters!
Mounting the Camera
1. Please attach the included mounting
adapter to the computer and possibly moni-
tor arm. The actual combination will vary and
depend on your mounting and computing
hardware.
2. Push the camera module carefully onto the rods
until the front is approximately aligned with the
monitor plane.
3. Carefully tighten the
lock screw on the bottom
with a Philips screw driver.
4. Connect the USB cable
to an available USB2/3
port on the computer.
USB Cable Options
The camera is available with either 0,5 or 1m USB2 cable. Above 1m cable
length the system might report a 'cable too long' error due to electrical
limitations. A small, external power supply to supplement the USB port is
available as an option.
Maintenance
The camera contains no serviceable parts. Please clean the acrylic front
plate with a soft cloth, i.e. micro-fibre and avoid harsh cleaners. The IR-glass
mirror should be cleaned using isopropyl alcohol and a cotton swab.
1