Long term event history

The system stores the last two full triggers in memory. These are not erasable. Each time the unit sees a full trigger, the older of the two triggers
in memory will be replaced by the new trigger. To access long term event history:
1.
With the ignition off, press and hold the Control center button.
2.
Turn on the ignition.
3.
Release the Control center button.
4.
Press and release the Control center button within 5 seconds. The LED will flash in groups indicating the last two zones that triggered the
unit. The LED will flash for one minute or until the ignition is turned off.
NOTE: The Warning Zone triggers are not stored to memory and will not be reported.

Table of zones

Use the Table of Zones diagnostic function to see which input triggered the system. It can also help to determine which input to use when con-
necting optional sensors and switches.
.
Zone No
Trigger Type
1
Instant Trigger
2
Multiplexed Shock Sensor Input
Door Trigger
3
Multiplexed Shock Sensor Input
4
Ignition
5
6
Hood Trigger

Remote Start shutdown diagnostics

To perform shutdown diagnostics:
1.
With the ignition OFF, press and hold the Control center button.
2.
Turn the ignition ON and then back OFF while holding the Control center button.
3.
Release the Control center button.
4.
Press and release the Control center button. The LED flashes to report the last shutdown for one minute or until the ignition is turned on,
as shown in the following table:
LED Flashes
Shutdown Mode
1
Timed out
2
Over-rev shutdown
3
Low or no RPM, low battery (for voltage and virtual tach modes)
4
Transmitter shutdown (or optional push button)
5
(-) Hood Shutdown (H3/4 GRAY)
6
(+) Shutdown (H3/3 BROWN)
7
(-) Neutral safety shutdown (H3/1 BLACK/WHITE)
8
Wait-to-start timed out
© 2012 Directed. All rights reserved.
Input Description
BLUE (H1/7)
Mux BLUE sensor port wire.
GREEN (H1/8) and VIOLET (H1/6).
Mux GREEN wire
Yellow ribbon harness wire
GRAY on the 6-pin shutdown harness