A
A) End of shaft with nut
B) Washer
C) Elbow
Liquid gas
Use the rubber pipe holder for liquid gas. Al-
ways engage the gasket. Then continue with
the gas connection.
The flexible pipe is prepared for apply when:
– it can not get hot more than room tempera-
ture, higher than 30°C;
– it is no longer than 1500 mm;
– it shows no throttles;
– it is not subject to traction or torsion;
– it does not get in touch with cutting edges
or corners;
– it can be easily examined in order to make
sure its condition.
The control of preservation of the flexible pipe
consists in checking that:
– it does not show cracks, cuts, marks of
burnings on the two ends and on its full
length;
– the material is not hardened, but shows its
correct elasticity;
– the fastening clamps are not rusted;
– expired term is not due.
If one or more defects are visible, do not repair
the pipe, but replace it.
Important! When installation is complete,
make sure that the seal of each pipe fitting is
correct. Use a soapy solution, not a flame!
Injectors replacement
1. Remove the pan supports.
2. Remove the caps and crowns of the burn-
er.
1) only for Russia
10
B C
3. With a socket spanner 7 remove the in-
jectors and replace them with the ones
which are necessary for the type of gas
you use (see table in "Technical Informa-
tion" chapter).
4. Assemble the parts, follow the same pro-
cedure backwards.
5. Replace the rating plate (it is near the gas
supply pipe) with the one for the new type
of gas supply. You can find this plate in
the package supplied with the appliance.
If the supply gas pressure is changeable or
different from the necessary pressure, you
must fit an applicable pressure adjuster on the
gas supply pipe.
Adjustment of minimum level
To adjust the minimum level of the burners:
1. Light the burner.
2. Turn the knob on the minimum position.
3. Remove the control knob.
4. With a thin screwdriver, adjust the by-
pass screw position.
A) The by-pass screw
• If you change from natural gas G20 20
mbar (or natural gas G20 13 mbar
uid gas, fully tighten the by-pass screw in.
• If you change from liquid gas to natural gas
G20 20 mbar, undo the by-pass screw ap-
proximately 1/4 of a turn.
• If you change from natural gas G20 20
mbar to natural gas G20 13 mbar
the by-pass screw about 1/4 of a turn.
• If you change from liquid gas to natural gas
1)
G20 13 mbar
, undo the by-pass screw
about 1/2 of a turn.
A
1)
) to liq-
1)
undo
www.zanussi.com