Clearance Heights

The cooker hood is designed to be fitted over a
cooking appliance at the clearance heights stated,
providing the maximum output of the appliance
beneath does not exceed the maximums quoted in
the Technical Specifications.
If the output of the appliance below the cooker
hood exceeds the maximum outputs quoted,
please refer to the cooker manufacturer's
installation instructions.
A minimum clearance height of 650 mm (25
is required when installed above a built-in electric
hob, or 700 mm (27
1/2
built-in gas hob.
A minimum clearance height of 685 mm (27 ins) is
required when installing above a slot-in electric
cooker, or 787 mm (30
a slot-in cooker.
When installed between adjoining wall cabinets,
the wall cabinets must not overhang the hob and
the distance between the underside of the cabinet
and the worktop must be 450 mm (17
of 50 mm (2 ins) must be maintained either side of
the hob.
This cooker hood must not be installed
above a cooking appliance with a high
level grill.
1/2
ins) when installed above a
ins) when installed above
1/2
ins), a gap
1/2
ins)
A: Built-in Electric Hob:
B: Built-in Gas hob:
C: Slot-in Electric Cooker: 685mm minimum clearance
D: Slot-in Gas Cooker:
12
Hob
650mm minimum clearance
700mm minimum clearance
787mm minimum clearance
Fig. 6