Clarke BANDIT Руководство по эксплуатации и техническому обслуживанию - Страница 6
Просмотреть онлайн или скачать pdf Руководство по эксплуатации и техническому обслуживанию для Воздушный компрессор Clarke BANDIT. Clarke BANDIT 11 страниц.
Pre-Operation Checks
Before using your compressor it is necessary to perform the following operations, ensuring
the unit is NOT plugged into the mains supply.
1. Remove the Oil Filler Travel
plug and fill with the SAE 30
oil supplied, to the centre of
the red dot on the oil sight
glass.
2. Screw in the Breather
3. Screw the air filter,
supplied, into the
cylinder head, fully.
4. Screw in the Tap and Regulator sub assembly
tightly, (see Figs 3 & 4), noting that PTFE tape is
already in place. Ensure the tap is uppermost.
5. The pressure regulator should be set to its lowest
setting e.g. turned fully anti clockwise.
6. Check that the air receiver drain valve at the
base of the receiver is fully CLOSED.
7. Ensure the machine is located on a
level surface in a clean dry
environment with adequate ventilation
and plenty of air flow around the unit.
DO NOT place any materials
whatsoever on the unit.
8.
Now connect the air hose to the air outlet, and at the other end to the air tool -
screwed on directly.
IMPORTANT: When using the compressor for the first time, open the drain cock and run the
compressor for at least 10 minutes, off load, in order for full lubrication to take place (see
operation which follows).
Once this is done, allow the compressor to sit for a minute or two, then recheck the oil level.
Remove the breather and top up to the middle of the dot in the oil sight glass if necessary.
Fig.1
Fig.2
- 6 -
Fig.3
Tap and Regulator
sub-assembly