Clarke CHAMP 262 Инструкции по эксплуатации и техническому обслуживанию - Страница 9
Просмотреть онлайн или скачать pdf Инструкции по эксплуатации и техническому обслуживанию для Воздушный компрессор Clarke CHAMP 262. Clarke CHAMP 262 12 страниц.
Fault Finding
Always disconnect the compressor from the electrical supply and
Problem
Compressor stops and
will not restart.
Unable to adjust air
outlet pressure.
Air leaking from pressure
switch when the
compressor is not
running.
Compressor will not start
or stop automatically
Compressor runs
continuously, will not
reach pressure.
Compressor overheats.
Compressor noisy.
WARNING!
Probable cause
Compressor overloaded and thermal overload
protection has operated - remedy the cause of the
overload, then reset the overload trip (see figure 7).
Fuse blown - check and replace. If the fuse blows
repeatedly have the compressor checked.
Pressure regulator faulty - check and replace if
necessary.
Non-return valve leaking - disassemble non-return
valve, clean or replace if necessary.
Defective automatic pressure switch - have the
pressure switch checked and replaced if necessary.
Air filter blocked - clean filter.
Air leaks - check hoses and couplings.
Valves dirty or blocked - have compressor serviced.
Compressor may be too small for your application.
Air filter blocked - clean filter.
Insufficient ventilation - relocate compressor.
Low oil level - check oil.
Motor cooling fins dirty - clean compressor exterior.
Valves dirty or blocked - have compressor serviced.
Loose bolts - tighten.
Valve broken - have compressor serviced.
Bearings worn - have the bearings checked and
replaced if necessary.
9