Electrical Connections
110V Model
Connect the mains lead to a suitable 110V (50Hz) electrical supply through anapproved
plug to BS4343, or a suitably fused isolator switch. If using a portable 110V transformer,
make sure it has a rated capacity sufficientto take the load of the air compressor (see
specifications on page 20).0 Volt (50Hz) electrical supply through an approved 13 amp
BS 1363 plug, or a suitably fused isolator switch.
230V Model
The mains lead should be connected to a standard 230Volt (50Hz) electrical supply through
an approved 13Amp BS 1363 plug or a suitably fused isolator switch.
WARNING! THIS APPLIANCE MUST BE EARTHED
IMPORTANT: The wires in the mains lead are coloured in accordance with the following
code:
Green & Yellow
Blue
Brown
As the colours of the flexible lead of this appliance may not correspond with the coloured
markings identifying terminals in your plug proceed as follows:
•
Connect GREEN & YELLOW cord to terminal marked with a letter "E" or Earth symbol
"
" or coloured GREEN or GREEN & YELLOW.
•
Connect BROWN cord to terminal marked with a letter "L" or coloured RED.
•
Connect BLUE cord to terminal marked with a letter "N" or coloured BLACK.
If this appliance is fitted with a plug which is moulded onto the electric cable (i.e. non-
rewireable) please note:
1. The plug must be thrown away if it is cut from the electric cable.
There is a danger of electric shock if it is subsequently inserted into a socket outlet.
2. Never use the plug without the fuse cover fitted.
3. When replacing a detachable fuse carrier, ensure the correct replacement is used
(as indicated by marking or colour code).
4. Replacement fuse covers can be obtained from your local dealer or most electrical
stockists.
Fuse Rating
The fuse in the plug must be replaced with one of the same rating (13 amps) and this
replacement must be ASTA approved to BS1362.
We strongly recommend that this machine is connected to the mains supply via a Residual
Current Device (RCD)
If in any doubt, consult a qualified electrician. DO NOT attempt any repairs yourself.
-
Earth
-
Neutral
-
Live
10
Operating Instructions
Switching the air compressor ON
The compressor will make a continuous loud noise when the tank is charging -
this is normal.
1.
Lift the red On/Off switch.
• The compressor will charge the
main tank to10 bar (145 psi) then
switch off.
• The compressor will restart
automatically whenever the
pressure in the main tank falls
below a certain level.
2.
Check the operation of the safety
valve, under pressure, daily by
pulling the ring as shown in figure 6.
Air should be released you pull the
ring and stop when the ring is
released.
• If the valve does not operate as described, or if the valve is stuck, it must
be replaced by qualified service personnel before using the compressor.
WARNING!
Do not remove or attempt to adjust the safety valve.
3.
Select the pressure you need using
the pressure regulator. See figure 7.
4.
Open the outlet tap.
Figure 10
Figure 6
Pressure
regulator
Output
pressure
gauge
Figure 7
15