Clarke PEH16 Руководство по эксплуатации и техническому обслуживанию - Страница 10
Просмотреть онлайн или скачать pdf Руководство по эксплуатации и техническому обслуживанию для Воздушный компрессор Clarke PEH16. Clarke PEH16 17 страниц. Air compressor electric motor driven
TROUBLESHOOTING CHART
1. Any remedial work that may be required must be carried out by a qualified
electrician/engineer.
2. Disconnect from the mains supply before removing any parts from the
compressor.
3. Empty Air Receiver of Air before dismantling any part of the compressor
unit's pressure system.
4. If your compressor develops a fault do not use until the fault has been
rectified.
SYMPTOM
Compressor will
not start
automatically
Bleed valve
under pressure
switch blows
whilst
compressor is
not running
Bleed valve
under pressure
switch blows
whilst
compressor is
running
Compressor unit
will not stop
automatically.
Parts & Service: 020 8988 7400 / E-mail: [email protected] or [email protected]
IMPORTANT
PROBABLE CAUSE
Fault in electrical installation
Current supply failure.
Voltage drop.
Motor starter faulty.
Motor incorrectly connected or
faulty
Starter overload has
out.
Pressure switch defective.
Fuse blown.
Non-return valve leaking.
Relief valve leaking.
Pressure switch defective.
!
REMEDY
Let an electrician check
electrical installation.
tripped
Reset by depressing button.
Have pressure switch
changed by an electrician.
Check fuse rating - replace.
Clean non-return valve or
replace.
Clean relief valve or change
pressure switch.
Contact Clarke Service
10