MAINTENANCE

DAILY
1. Check the oil level before you start and top up if necessary - use Clarke
Synthetic Air Compressor Oil ONLY, available from your Clarke dealer...
Part No. 3050795
The oil level is checked by viewing the oil
sight glass, shown arrowed in Fig. 5
To add oil, proceed as follows:
Remove the oil filler plug, shown
arrowed in Fig. 6, and top up until the
oil level is midway on the oil sight glass.
Take great care not to cross thread the
filler plug when replacing.
IMPORTANT:
DO NOT replace the oil filler plug with
anything other than the original, as the filler
plug doubles as an air breather
2. Drain any condensate that may have accumulated in the air outlet filter, by
pushing the valve (E Fig. 3), upwards.
3. When you have finished with the compressor, ALWAYS open the drain valve -
at the base of the tank, to expel all air, and to allow any
condensate to drain off.
DO NOT FORGET to close the valve again when the tank is empty.
PERIODICALLY
1. Renew Oil Filler Plug/Air Breather every 500 hours of operation.
2. If oil becomes contaminated it will be necessary to drain it by removing the
filler plug/air filter, inverting the compressor and allowing time for the oil to
drain, before filling with new SYNTHETIC OILto the middle of the oil sight glass.
9
Fig.5
Fig.6