1. Motor
The RED wire of the motor should be connected into the "1" terminal.
The GREEN wire of the motor should be connected into the "2" terminal.
2. Limit Switches
The RED wire of the limit switches should be connected into the "3" terminal.
The BLACK wire of the limit switches should be connected into the "4" terminal.
The YELLOW wire of the limit switches should be connected into the "5" terminal.
3. Alarm Lamp (24VDC)
The RED wire of the alarm lamp should be connected into the "6" terminal.
The WHITE wire of the alarm lamp should be connected into the "7" terminal.
4. Battery
The positive terminal of the battery should be wired to the "8" terminal.
The negative terminal of the battery should be wired to the "9" terminal.
Recommend strongly to use the controller LM118 (WA4004 ) to connect Battery with battery's
Terminal of control board if the battery is used as the primary power supply in system (such as SOL
PLUS KIT). Please refer to the user manual of control LM118 ( WA4004 ) separately.
5. External Receiver
The RED wire of the external receiver should be connected into the "12" terminal.
The BLACK wire of the external receiver should be connected into the "13" terminal.
The BROWN wire of the external receiver should be connected into the "14" terminal.
6. Push Button
The push button should be wired to the "14" and "15" terminals. The gate operator works alternately by
pushing the button (open-stop-close-stop-open).
7. Wired Keypad (24VDC)
The RED wire of the wired keypad should be connected into the "12" terminal.
The BLACK wire of the wired keypad should be connected into the "13" terminal.
The BLUE wire of the wired keypad should be connected into the "14" terminal.
The WHITE wire of the wired keypad should be connected into the "15" terminal.
8. Photocell
Use a 2-core cable to connect the "+ ~" terminal of the photocell's emitter to the "12" terminal, the "- ~"
terminal to the "13" terminal. Also the "+ ~" and "- ~" terminals of the photocell's receiver should be
connected to the "12" and "13" terminals in parallel.
Use another 2-core cable to connect the "COM" terminal of the receiver to the "16" terminal, the "NC"
terminal to the "17" terminal.
9. Loop Detector
First insert the LOOP DETECTOR BOARD into the CONTROL BOARD, and then connect the twisted-pair
to the "18" and "19" terminals.