Directed Electronics 3100 Руководство по установке - Страница 14

Просмотреть онлайн или скачать pdf Руководство по установке для Автомобильная сигнализация Directed Electronics 3100. Directed Electronics 3100 16 страниц. Car security

Directed Electronics 3100 Руководство по установке
OFF: the door unlock output provides a single pulse.
ON: the door unlock output provides a double pulse.
7.
Code Hopping
ON: The code hopping portion of messages from the remote con-
trols are decrypted before a command is activated
OFF: The code hopping portion of the remote control messages are
ignored resulting in possible range improvement.
8.
Door Trigger Error Chirp
ON: If the door trigger is active when arming, the siren emits 1
additional chirp to alert you.
OFF: An active door trigger when arming does not generate an
alert output.
9.
Double Pulse Lock
OFF: Lock output provides a single pulse.
ON: Lock output provides a double pulse.
10. Comfort Closure
OFF: Comfort Closure is defeated when arming.
On: 800mS after door lock pulse or 2nd pulse for double setting.
Door lock output turns on again for 20 seconds.
Important: If the unit is disarmed while the 20 second timer is active
when closing the windows, Comfort Closure output immediately stops
before the doors unlock.
The alarm system does not monitor zone inputs for bypass notification,
Warn Away, or full trigger inputs - until the 20 second timer is completed.
This avoids any false system triggering while the windows are in motion.
12