SER 7818-F5
3. Unscrew Nut and Handle Assembly (74) on Follower
Plate Assembly (78).
• This allows air trapped underneath the Follower
Plate to bleed.
4. Place the Hoist's Valve Handle in the Up position.
5. Center the container onto Base (27) once the hoist
stops.
• Make sure each Shoe (32) properly secures the
container.
6. Place the Hoist's Valve Handle in the Down position.
• Allow the Follower Plate to enter the container.
Force will cause product to appear at the Follower
Plate's bleed valve and the hoist should stall.
7. Screw the Nut and Handle Assembly securely on the
Follower Plate.
CAUTION
Leaving the Hoist's Valve Handle in the Down posi-
tion may cause the material to bypass the fol-
lower's wiper hoses.
Whether to place the Hoist's Valve Handle in the
Neutral position or maintain the Down position is
dependent on the:
• viscosity of the material being pumped
• amount of line pressure to the hoist
Dependent Step
8. Place the Hoist's Valve Handle in the Neutral position
as required.
9. Rotate the Pump's Valve Handle to the On position.
Preventive Maintenance
Daily
Inspect for Air and/or Material Leakage
Table 2
Revision (6-04)
1-800-548-1191-http://[email protected]
Attach gun to Fitting (22) and add 2 oz. (59 cc) of clean SAE 30 oil to each column
Pump Hoist Model 7818-F5 Preventive Maintenance Schedule
12
Pump Hoist and Power Ram
10. Check the motor for air leakage.
If the motor leaks, refer to the Troubleshooting Chart
in the Air Motor Service Guide for details.
11. Operate the control valve into a container.
12. Allow the pump to cycle until the product is free of air.
If the pump assembly does not prime, refer to the
Troubleshooting Chart in the Pump Service Guide for
details.
13. Shut off the control valve.
14. Visually inspect the pump for external leaks.
• The pump should not cycle.
If the pump does not stall, refer to the
Troubleshooting Chart in the Pump Service Guide for
details.
Once the Container is Empty
15. Place the Follower Plate's Valve Handle to the On
position (in line with the hose).
16. Place the Hoist's Valve Handle in the Up position.
Air enters beneath the follower plate to assist the hoist.
Once the follower plate is free of the container:
17. Place the Hoist's Valve Handle in the Neutral
position.
18. Place the Follower Plate's Valve Handle in the Off
position.
Yearly
Alemite Corporation