-SO Sensor Operation Range Adjustment
1.
Make sure power supply is disconnected
from sensor and make short circuit on
red wires. See DETAIL A.
2.
Connect power supply to sensor.
3.
Move hand in front of sensor to distance
of 2" to 4" within 5 seconds.
4.
Wait until red light flashes quickly and
move hand to desired sensing distance.
See DETAIL B.
5.
Hold hand at desired sensing distance
until red light stops flashing. See
DETAIL C.
-SO Sensor Operation - Standard
Valve Shown Upright For Reference Only
L1000802
By Others
Transformer must be
plugged into a GFI protected
circuit. Fixture must be earth
grounded per N.E.C. or
applicable codes.
6 of 12
Jumper
DETAIL A
DETAIL B
DETAIL C
Rev. H – 03/07/05