Clarus Technologies WCS-25 Руководство по эксплуатации - Страница 11
Просмотреть онлайн или скачать pdf Руководство по эксплуатации для Оборудование для уборки Clarus Technologies WCS-25. Clarus Technologies WCS-25 16 страниц. Cleaning stations
Также для Clarus Technologies WCS-25: Руководство по эксплуатации (14 страниц)
VII.
CARE AND MAINTENANCE
A.
Sump Maintenance
(Standard on PCS/WCS; Optional on RPW/RWC Models). The PCS/WCS models are
equipped with a sump pump to remove the accumulated sludge from the bottom of the
tank. This is an optional feature in the RPW/RWC models. The pump interval depends
on usage. For motor pools this interval is 3-6 months. For weapons cleaning this
interval is 6 months to 1 year.
Watch a video on how to pump out sludge at
new/#howtovideo
To dump the sump, first remove the hose on the front right side of the unit, remove the
cap and put it either in a bucket or barrel and turn the hose end valve on. Second, open
the yellow valve handle on the main shelf. Third, move the handle back and forth on the
sump pump located on the shelf. Pump the sump out till the solvent changes color. This
usually takes 2-5 gallons. Turn off hose end valve, yellow handle valve, replace cap and
return it to its hangar. Dispose of waste properly.
B.
Canister Lid O-Ring Maintenance
Every time the filters are changed, smear a small amount of petroleum jelly around the
o-ring to keep it lubricated.
WARNING!
ALWAYS WEAR GLOVES AND EYE PROTECTION WHEN
HANDLING SOLVENT OR FILTERS.
WARNING! When changing filters, make sure to have something underneath the
used filter as you move it, such as a bucket or oilsorb, to capture any incidental
drips.
C.
Changing Filters.
Watch a how-to video on changing filters online at
new/#howtovideo
The Cleaner comes equipped with one or two 5" X 18" filter canisters. Inside these
canisters are 4.5" X 17" filter cartridges. These filters need to be changed when
indicated by the filter status lights (older models) or by a 40 PSI reading on the pressure
gauge mounted on the filter canisters (standard feature for PCS/WCS models; Optional
for RPW/RWC models). If your unit has neither feature, the recommended change
interval for motor pools is 3-6 months. For weapons cleaning the filter change interval
is 6 months to 1 year. If the Cleaner receives heavy usage, the change interval may need
to be adjusted accordingly as the quality of the solvent will be degraded.
When the gauge or lights indicate a filter change or the recommended time interval has
been reached, follow these steps to change the filters:
1. Turn all power to the system off.
http://www.clarustechnologies.com/whats-
www.clarustechnologies.com/whats-
11