CLAS HU 0180 Руководство - Страница 11

Просмотреть онлайн или скачать pdf Руководство для Сервисное оборудование CLAS HU 0180. CLAS HU 0180 16 страниц. 24l suction and 80l waste drainer

CLAS HU 0180 Руководство
WASTE OIL/SUCTION DRAINERS
To drain used oil from the tank
Close all valves on the product. Connect the air coupler to the air inlet connection
Close the valve (8) when the pressure reaches 0.5 bar.
WARNING !
Never change the settings of the safety valve above the tank. Changing the settings or removing
the safety valve may cause injury or damage to the product.
Mount the oil drain pipe (11) on the tank, which is intended for used oil.
Ensure environmental protection.
Open the oil drain valve (12) and drain.
Mounting the rod (HU 0149/ HU 0159)
Unscrew the bakalite bolt (13) and adjust the basin pipe for your work. Then screw the bakalite
bolt back on for more stability.
Open the valve (14) under the basin and drain the oil.
Caution: Before opening the valve, check the tank. If there is pressurized air inside the tank, for
your safety, you must discharge it.
Valve
Raccord d'entrée d'air
13
14