Specific microprocessors:
Microprocessor Intel Xeon E5-2690, 135 W:
Microprocessor models with 115 W and 130 W:
Humidity
Server on: 8% to 85%, maximum dew point 24 °C, maximum rate of change 5 °C/hr
Server off: 8% to 85%, maximum dew point 27 °C
Design to ASHRAE Class A3, ambient of 36 °C to 40 °C (96.8 °F to 104 °F), with relaxed support:
Supports cloud like workload with no performance degradation acceptable (Turbo-Off).
Under no circumstance can any combination of worst case workload and configuration result in
system shutdown or design exposure at 40 °C.
Electrical
Models with 750 W power supplies:
100 to 127 (nominal) V ac; 50 Hz or 60 Hz; 8.9 A
200 to 240 (nominal) V ac; 50 Hz or 60 Hz; 4.5 A
Input kilovolt-amperes (kVA) (approximately):
Models with 550 W power supplies:
100 to 127 (nominal) V ac; 50 Hz or 60 Hz; 6.5 A
200 to 240 (nominal) V ac; 50 Hz or 60 Hz; 3.3 A
Input kilovolt-amperes (kVA) (approximately):
BTU output
Minimum configuration: 461 Btu/hr (135 watts)
Maximum configuration: 2900 Btu/hr (850 watts)
Noise level
6.5 bels (operating)
6.3 bels (idle)

Warranty options

The System x3550 M4 has a three-year warranty with 24x7 standard call center support and 9x5 Next
Business Day onsite coverage. Also available are Lenovo Services warranty maintenance upgrades and post-
warranty maintenance agreements, with a well-defined scope of services, including service hours, response
time, term of service, and service agreement terms and conditions.
Lenovo warranty service upgrade offerings are country-specific. Not all warranty service upgrades are available
in every country. For more information about Lenovo warranty service upgrade offerings that are available in
your country, visit the Lenovo Services website:
https://www-304.ibm.com/sales/gss/download/spst/servicepac
System x3550 M4 (E5-2600 v2) (withdrawn product)
Temperature: 10 °C to 27 °C (50 °F to 80.6 °F)
Altitude: 0 to 304.8 m (1,000 ft)
Temperature: 10 °C to 35 °C (50 °F to 95 °F)
Altitude: 0 to 914.4 m (3,000 ft)
Minimum configuration: 0.14 kVA
Maximum configuration: 0.9 kVA
Minimum configuration: 0.14 kVA
Maximum configuration: 0.66 kVA