Additional Assistance
For more information, contact your local Armstrong Representative. Your local Representative will be able to supply you with
the following:
•
Humid-A-ware™ Software — For detailed information on customizing humidification schedules and calculating
non-wetting distances and humidification loads, refer to Armstrong's Humid-A-ware humidification sizing and
selection software. It can be downloaded from Armstrong's web site at www.armstrong-intl.com.
•
Humidification Solution Source Bulletin 596 — Provides information on different types of humidification methods
along with detailed description of Armstrong's complete line of humidification products.
•
Video Tapes - It's The Humidity — Part one is a video documentary covering the essentials of humidity and
outlining the primary reasons for humidity control. What is humidity? Relative humidity? What is dew point?
Enthalpy? How does evaporation affect comfort? How does humidity conserve energy? All of these questions in
practical and entertaining demonstrations.
Part two is a look at the four basic methods of large-scale humidification. Through animation, the tape discusses
the operation of evaporative pan, wetted element, water spray and steam humidifiers, and rates their ability to
meet efficiency, maintenance, controllability, sanitation and cost requirements.
•
Application Guidelines — Discusses specific humidity control problems and applications in a detailed
problem/solution format.
•
Installation and Maintenance — IB-52—Repair and adjustment for Honeywell MP 953-B, F. Also gives bonnet
seal replacement and stem adjustment.
•
Installation and Maintenance — IB-53—Repair and adjustment for Armstrong C-1801 Pneumatic operator. Also
gives start point adjustment, and valve and seat repair.
•
Installation and Maintenance — IB-61 — Armstrong A-5503 Pneumatic Temperature Switch application, operation
and installation.
•
Installation and Maintenance — IB-62 — Troubleshooting Guide for solenoid operated steam humidifiers. Tells
what to check for when valve will not open, close or the coil burns out.
•
Installation and Operation — Bulletin 549 — Humidifiers for Direct Area Humidification.
Limited Warranty and Remedy
Armstrong International, Inc. ("Armstrong") warrants to the original user of those products supplied by it and used in the service and in the manner for which
they are intended, that such products shall be free from defects in material and workmanship for a period of one (1) year from the date of installation, but not
longer than 15 months from the date of shipment from the factory, [unless a Special Warranty Period applies, as listed below]. This warranty does not
extend to any product that has been subject to misuse, neglect or alteration after shipment from the Armstrong factory. Except as may be expressly provided
in a written agreement between Armstrong and the user, which is signed by both parties, Armstrong DOES NOT MAKE ANY OTHER REPRESENTATIONS
OR WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR ANY
IMPLIED WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE.
The sole and exclusive remedy with respect to the above limited warranty or with respect to any other claim relating to the products or to defects or any
condition or use of the products supplied by Armstrong, however caused, and whether such claim is based upon warranty, contract, negligence, strict liability,
or any other basis or theory, is limited to Armstrong's repair or replacement of the part or product, excluding any labor or any other cost to remove or install
said part or product, or at Armstrong's option, to repayment of the purchase price. As a condition of enforcing any rights or remedies relating to Armstrong
products, notice of any warranty or other claim relating to the products must be given in writing to Armstrong: (i) within 30 days of last day of the applicable
warranty period, or (ii) within 30 days of the date of the manifestation of the condition or occurrence giving rise to the claim, whichever is earlier. IN NO
EVENT SHALL ARMSTRONG BE LIABLE FOR SPECIAL, DIRECT, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES, INCLUDING, BUT NOT
LIMITED TO, LOSS OF USE OR PROFITS OR INTERRUPTION OF BUSINESS. The Limited Warranty and Remedy terms herein apply notwithstanding
any contrary terms in any purchase order or form submitted or issued by any user, purchaser, or third party and all such contrary terms shall be deemed
rejected by Armstrong.
Special Warranty Periods are as follows:
Series EHU-700 Electric Steam Humidifier, Series HC-4000 HumidiClean Humidifier and
GFH Gas Fired Humidifier with Ionic Beds:
Two (2) years after installation, but not longer than 27 months after shipment from Armstrong's factory.
Armstrong Humidification Group
816 Maple Street, Three Rivers, Michigan 49093 – USA Phone: (269) 273-1415 Fax: (269) 273-9500
www.armstronginternational.com
Bulletin No. 544-I 8/06
Printed in U.S.A.